Simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations by MEKC.

نویسندگان

  • Ceren Yardimci
  • Nuran Ozaltin
چکیده

A micellar electrokinetic capillary chromatography method was developed and validated for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations. The influence of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, capillary temperature, applied voltage, and injection time was investigated, and the method validation studies were performed. The optimum separation for these analytes was achieved in less than 10 min at 30 degrees C with a fused-silica capillary column (56 cm x 50 microm i.d.) and a 25mM borate buffer at pH 9.0 containing 25mM SDS and 10% (v/v) acetonitrile. The samples were injected hydrodynamically for 3 s at 50 mbar, and the applied voltage was +30.0 kV. Detection wavelength was set at 238 nm. Diflunisal was used as internal standard. The method was suitably validated with respect to stability, specificity, linearity, limits of detection and quantification, accuracy, precision, and robustness. The limits of detection and quantification were 1.0 and 2.0 microg/mL for both ezetimibe and simvastatin, respectively. The method developed was successfully applied to the simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Spectrophotometric Determination of Ezetimibe and Simvastatin in Pharmaceutical Preparations Using Chemometric Techniques

Two spectrophotometric methods are described for the simultaneous determination of ezetimibe (EZE) and simvastatin (SIM) in pharmaceutical preparations. The obtained data was evaluated by using two different chemometric techniques, Principal Component Regression (PCR) and Partial Least-Squares (PLS-1). In these techniques, the concentration data matrix was prepared by using the mixtures contain...

متن کامل

Simultaneous estimation of simvastatin and ezetimibe by RP-HPLC in pure and pharmaceutical dosage form

A simple, precise and rapid RP-HPLC method was developed for the simultaneous determination of simvastatin and ezetimibe in combined pharmaceutical dosage forms. The method was carried out on a Shim-pack, RP-C18 column using a mixture of acetonitrile: methanol: buffer (triethylamine pH-3) in the ratio 15:45:40 and detection was done at 240 nm using external standard method as quantitation. The ...

متن کامل

Simultaneous Determination of Ezetimibe and Simvastatin in Pharmaceutical Dosage form by Validated RP-HPLC and UV- Spectrophotometric Methods

A simple, rapid and precise method is developed for the quantitative simultaneous determination of Ezetimibe and Simvastatin in combined pharmaceutical-dosage forms. Two methods are described for the simultaneous determination of Ezetimibe and Simvastatin. The first method was based on UVSpectrophotometric determination of two drugs, using simultaneous equation method. It involves absorbance me...

متن کامل

Stability Indicating RP-HPLC Method for Simultaneous Determination of Simvastatin and Ezetimibe from Tablet Dosage Form

A simple, specific and sensitive reverse phase high performance liquid chromatographic method was developed and validated for simultaneous determination of ezetimibe and simvastatin from pharmaceutical dosage forms. The method uses C18 ODS Hypersil column and isocratic elution. The mobile phase composed of acetonitrile:phosphate buffer (pH 4.5, 0.01M) in the ratio of 65:35 v/v was used at a flo...

متن کامل

Microemulsion Liquid Chromatographic Method for Simultaneous Determination of Simvastatin and Ezetimibe in Their Combined Dosage Forms

A rapid HPLC procedure using a microemulsion as an eluent was developed and validated for analytical quality control of antihyperlipidemic mixture containing simvastatin (SIM) and ezetimibe (EZT) in their pharmaceutical preparations. The separation was performed on a column packed with cyano bonded stationary phase adopting UV detection at 238 nm using a flow rate of 1 mL/min. The optimized mic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 48 2  شماره 

صفحات  -

تاریخ انتشار 2010