Real-time fit of a respirator during simulated health care tasks.
نویسندگان
چکیده
Fit is an important but difficult-to-predict feature of respirator performance. This study examined a new approach to measuring respirator performance using two continuous direct-reading particle-counting instruments in a simulated health care workplace. A pilot test was conducted with eight experienced health care professionals who passed a traditional quantitative fit test before performing three randomized 10-min health care scenarios (patient assessment [PA], IV treatment [IV], and wound care [WC]). Two TSI Portacount Plus (Model 8020) with N95 Companion (Model 8095) instruments were used to continuously measure 1-sec ambient particle concentrations inside and outside the respirator facepiece. A simulated workplace protection factor (SWPF) was calculated by dividing outside by inside concentrations. Data were log transformed and examined using analysis of variance (ANOVA) between subjects, scenario types, and scenario order. The GM SWPF for the eight subjects, three scenarios per subject, ranged from 172 to 1073 (GSD 1.7 to 3.5) and was significantly different for each subject. A multi-way analysis of variance showed no difference between the three scenario types (PA, IV, WC). There were differences by the order in which scenarios were performed: the third scenario SWPF was significantly different and higher than that of the first and second scenarios. All subjects passed the initial quantitative fit test with a fit factor of at least 100. Five subjects had fit factors greater than 200 and GM scenario SWPFs greater than 400. Three participants with initial fit factors less than 200 had GM scenario SWPFs ranging from 132 to 326. This pilot test demonstrates that it is possible to evaluate instantaneous respirator fit using two quantitative fit test instruments in a simulated health care environment. Results suggest that an initial fit test may be predictive of fit during simulated tasks and that one scenario may be adequate for measuring a simulated workplace protection factor. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a video for subject D activities overlaid with simulated workplace protection factor data.].
منابع مشابه
Assessing real-time performances of N95 respirators for health care workers by simulated workplace protection factors
To assess performances of N95 respirators for Health Care Workers (HCWs) in a simulated health-care setting, we measured the Simulated Workplace Protection Factors (SWPFs) in real-time from the volunteers. A total of 49 study subjects, wearing 3 M respirator Model N95 1860 and 1860S, were fit tested using the OSHA Exercise Regimen. The test subjects were asked to perform simulated scenarios, in...
متن کاملA novel approach to fit testing of the N95 respirator in real time in a clinical setting
The instant measurements provided by the Portacount fit-test instrument have been used as the gold standard in predicting the protection of an N95 respirator in a laboratory environment. The conventional Portacount fit-test method, however, cannot deliver real-time measurements of face-seal leakage when the N95 respirator is in use in clinical settings. This research was divided into two stages...
متن کاملComparing the protective performances of 3 types of N95 filtering facepiece respirators during chest compressions
OBJECTIVE Healthcare providers in emergency departments should wear respirators for infection protection. However, the wearer's vigorous movements during cardiopulmonary resuscitation may affect the protective performance of the respirator. Herein, we aimed to assess the effects of chest compressions (CCs) on the protective performance of respirators. METHODS This crossover study evaluated 30...
متن کاملEvaluation of half-face respirator fit in an Iranian petrochemical company's workers
Introduction: The performance of respirator-face piece is depending on a good contact between the worker's face and the respirator. Improper sealing can cause reduction in performance of respirators to protect health and safety of workers against risks related to chemical agents at work. This study is aimed to evaluate the fitness of half-face respirators and other related factors on it in an...
متن کاملSurgical mask vs N95 respirator for preventing influenza among health care workers: a randomized trial.
CONTEXT Data about the effectiveness of the surgical mask compared with the N95 respirator for protecting health care workers against influenza are sparse. Given the likelihood that N95 respirators will be in short supply during a pandemic and not available in many countries, knowing the effectiveness of the surgical mask is of public health importance. OBJECTIVE To compare the surgical mask ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of occupational and environmental hygiene
دوره 9 10 شماره
صفحات -
تاریخ انتشار 2012