Directed air flow to reduce airborne particulate and bacterial contamination in the surgical field during total hip arthroplasty.

نویسندگان

  • Gregory W Stocks
  • Daniel P O'Connor
  • Sean D Self
  • Geoff A Marcek
  • Brandon L Thompson
چکیده

This study evaluated the use of a system that delivers a small field of local, directed air from a high-efficiency particulate air (HEPA) filter to reduce airborne particulate and airborne bacteria in the surgical field during total hip arthroplasty. Thirty-six patients were randomized into 3 groups: with directed air flow, with the directed air flow system present but turned off, and control. Airborne particulate and bacteria were collected from within 5 cm of the surgical wound. All particulate and bacterial counts at the surgical site were significantly lower in the directed air flow group (P < .001). The directed air flow system was effective in reducing airborne particulate and colony-forming units in the surgical field during total hip arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can Particulate Air Sampling Predict Microbial Load in Operating Theatres for Arthroplasty?

Several studies have proposed that the microbiological quality of the air in operating theatres be indirectly evaluated by means of particle counting, a technique derived from industrial clean-room technology standards, using airborne particle concentration as an index of microbial contamination. However, the relationship between particle counting and microbiological sampling has rarely been ev...

متن کامل

Predicting bacterial populations based on airborne particulates: a study performed in nonlaminar flow operating rooms during joint arthroplasty surgery.

BACKGROUND Prevention of postsurgical infection is preferable to treatment. Prevention requires identification and control of the potential sources of microbial contamination. This study investigated whether the density of airborne particulates can predict the density of viable airborne bacteria at the surgery site. METHODS A standard particle analyzer was used to measure the number and diame...

متن کامل

Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study.

BACKGROUND Recent studies have shown a higher rate of surgical site infections in hip prosthesis implantation using unidirectional airflow ventilation compared with turbulent ventilation. However, these studies did not measure the air microbial quality of operating theatres (OTs), and assumed it to be compliant with the recommended standards for this ventilation technique. AIM To evaluate air...

متن کامل

Current Evidence for the Use of Laminar Flow in Reducing Infection Rates in Total Joint Arthroplasty.

Since the introduction of laminar air flow in orthopaedic theatres by Sir John Charnley, it has widely become accepted as the standard during orthopaedic procedures such as joint arthroplasty. We present a review of available current literature for the use of laminar flow operating theatre ventilation during total joint arthroplasty and examines the effectiveness of laminar flow ventilated oper...

متن کامل

بررسی ذرات معلق و بیوآیروسل‌های باکتریایی در هوای تنفسی زندانیان

Objectives: Many of non-respiratory and respiratory disorders are associated with bioaerosols in indoor and outdoor air. The best conditions for bioaerosols life are high humidity and moderate temperatures, which exist usually in indoor spaces such as the prisons, where density of individual is high. Pathogen spreading centers cause the prisoners health at risk of disease outbreaks through airb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 2011