Usefulness of a Guiding Sheath for Fluoroscopic Colorectal Stent Placement
نویسندگان
چکیده
OBJECTIVE To investigate the technical feasibility, clinical usefulness, and safety of a guiding sheath in fluoroscopic stent placement for patients with malignant colorectal obstructions. MATERIALS AND METHODS Between June 2007 and January 2011, fluoroscopic placement of a dual colorectal stent was attempted in a total of 97 patients with malignant colorectal obstructions. A polytetrafluoroethylene guiding sheath was used in patients in whom a stent delivery system failed to reach the obstruction. Usefulness of the sheath was evaluated depending on whether the sheath could successfully assist the stent delivery system reach its area of interest. RESULTS The guiding sheath was needed in 22 patients (15 men, 7 women; age range, 33-77 years; mean age, 59 years). The overall success rate for passing the sheath to the area of interest was 100%. There were no procedure-related deaths or major complications. The majority of the patients reported mild discomfort. In 2 of 22 patients with successful passing of the sheath to the area of interest, stent placement failed because of failure in the negotiation of a guide wire through the obstruction. CONCLUSION Using a guiding sheath seems to be easy, safe and useful in fluoroscopic stent placement for patients with malignant colorectal obstructions.
منابع مشابه
The role of colorectal stent placement in the management of acute malignant obstruction.
BACKGROUND In recent decades, the use of colorectal stents for palliation or as a bridge to surgery in acute malignant colorectal obstruction has increased. We aimed to evaluate the technical and clinical efficacy, safety and clinical outcomes of endoscopic stenting for the relief of acute colorectal obstruction secondary to cancer. METHODS From March 2006 to December 2012, among 100 patients...
متن کاملThe Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon
OBJECTIVE We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. MATERIALS AND METHODS Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malign...
متن کاملFluoroscopy Guided Transurethral Placement of Ureteral Metallic Stents
Ureteral stent exchange is usually performed under both fluoroscopic and cystoscopic guidance. We experienced two cases with retrograde placement of metallic ureteral stent via urethra under fluoroscopic guidance. When patients with double-J ureteral stent (DJUS)have symptom and want to change DJUS to metallic stent, fluoroscopic guided transurethral placement of ureteral metallic stent is a go...
متن کاملFluoroscopic Placement of Double-Pigtail Ureteral Stents
PURPOSE Double-pigtail ureteral stent is placed cystoscopically after ureteroscopy. We describe a technique for fluoroscopic placement of ureteral stents and demonstrate its use in a non-randomized prospective study. MATERIALS AND METHODS Double-pigtail stents were placed either fluoroscopically or cystoscopically in 121 consecutive patients. In the fluoroscopic method, the stent was placed o...
متن کاملPalliation of malignant esophageal obstruction and fistulas with covered self expandable metallic stents: assessment of a simple fluroscopic method.
PURPOSE To introduce a convenient, quick and effective way to place self-expandable metal stents (SEMSs) to relieve dysphagia and fistula caused by esophageal carcinoma. MATERIALS AND METHODS A consecutive series of 36 patients (25 men, 11 women), aged 38-82 years (median, 52.7 years) underwent stent placement using a 7F long sheath of 55 cm and fully covered SEMS under local anesthesia with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 13 شماره
صفحات -
تاریخ انتشار 2012