Portable pressure wave - maker for leak detection and pipe system characterization

نویسنده

  • SILVIA MENICONI
چکیده

AND SILVIA MENICONI nterest in developing accurate and reliable leak detection methodologies has grown considerably within the technical–scientific community in recent years. Because of the change in natural hydrologic yields and growing resource consumption in many places, water recovered from leak detection and reduction efforts is increasingly valuable (Colombo & Karney, 2002). Presently, leak detection campaigns play an important role in pipe system management with real-time monitoring and continuous calibration of numerical models simulating pipe-system behavior. As a consequence, particular attention has been devoted to developing safe and effective leak-detection techniques. Until recently, only steady-state testing techniques were considered. In steady-state conditions, uncertainties about geometrical system characteristics and changes in flow conditions resulting from long test duration cause difficulties in accurate assessment. More encouraging results have been obtained using leak detection approaches based on the execution of fast transients that cause pressure surges compatible with the pipe’s structural integrity. Such approaches are attractive because of their brief duration and modest cost, both in terms of instrumentation and in the time necessary to complete tests. Compared with steady-state techniques, they are • much shorter in duration, significantly reducing interference with the regular functioning of the system and the probability of changes in flow conditions and • less influenced by pipe friction factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

INVERSE FREQUENCY RESPONSE ANALYSIS FOR PIPELINES LEAK DETECTION USING THE PARTICLE SWARM OPTIMIZATION

Inverse Transient Analysis (ITA) is a powerful approach for leak detection of pipelines. When the pipe transient flow is analyzed in frequency domain the ITA is called Inverse Frequency Response Analysis (IFRA). To implement an IFRA for leak detection, a transient state is initiated in the pipe by fast closure of the downstream end valve. Then, the pressure time history at the valve location is...

متن کامل

Effects of Flow Hydraulics, Pipe Structure and Submerged Jet on Leak Behaviour

The aim of this paper is numerical and experimental study of the effects of flow hydraulics, pipe structure (particularly elastic behaviour) and submerged jet on leak behaviour. In this regard, experimental tests were performed on a high-pressure circulation set up. Experiments were performed on an old steel pipe and a High Density Polyethylene (HDPE) pipe discharged to the atmosphere in a wide...

متن کامل

Statistical Review of Major Standpoints in Hydraulic Transient-Based Leak Detection

Today, pipe systems are the most common facilities to convey various fluids from one place to another. In such facilities faults like leaks lead to advert consequences such as economic losses and social health threats. The fact that early detection of leaks can play a prominent role in reducing the amount of these undesired impacts has absorbed noticeable attention from researchers to this fiel...

متن کامل

Remote pipeline assessment and condition monitoring using low-frequency axisymmetric waves: a theoretical study of torsional wave motion

Waves that propagate at low frequencies in buried pipes are of considerable interest in a variety of practical scenarios, for example leak detection, remote pipe detection, and pipeline condition assessment and monitoring. Particularly useful are the n=0, or axisymmetric, modes in which there is no displacement (or pressure) variation over the pipe cross section. Previous work has focused on tw...

متن کامل

Experimental and Numerical Simulation of Water Hammer in Water Conveyance Pipeline and Effect of Surge Tower Pipe in Controlling this Phenomenon

Water hammer is one of the unsteady flows in urban water distribution networks, which has been of great importance due to the damage caused to the pipeline and has always been of interest to researchers. In this study, the phenomenon of water hammer due to the sudden closure of the valve in the downstream end has been investigated in a laboratory and using a numerical model. In the laboratory s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008