Machine perfusion versus cold storage for preservation of kidneys from expanded criteria donors after brain death.

نویسندگان

  • Jürgen Treckmann
  • Cyril Moers
  • Jacqueline M Smits
  • Anja Gallinat
  • Mark-Hugo J Maathuis
  • Margitta van Kasterop-Kutz
  • Ina Jochmans
  • Jaap J Homan van der Heide
  • Jean-Paul Squifflet
  • Ernest van Heurn
  • Günter R Kirste
  • Axel Rahmel
  • Henri G D Leuvenink
  • Jacques Pirenne
  • Rutger J Ploeg
  • Andreas Paul
چکیده

The purpose of this study was to analyze the possible effects of machine perfusion (MP) versus cold storage (CS) on delayed graft function (DGF) and early graft survival in expanded criteria donor kidneys (ECD). As part of the previously reported international randomized controlled trial 91 consecutive heart-beating deceased ECDs--defined according to the United Network of Organ Sharing definition--were included in the study. From each donor one kidney was randomized to MP and the contralateral kidney to CS. All recipients were followed for 1 year. The primary endpoint was DGF. Secondary endpoints included primary nonfunction and graft survival. DGF occurred in 27 patients in the CS group (29.7%) and in 20 patients in the MP group (22%). Using the logistic regression model MP significantly reduced the risk of DGF compared with CS (OR 0.460, P=0.047). The incidence of nonfunction in the CS group (12%) was four times higher than in the MP group (3%) (P=0.04). One-year graft survival was significantly higher in machine perfused kidneys compared with cold stored kidneys (92.3% vs. 80.2%, P=0.02). In the present study, MP preservation clearly reduced the risk of DGF and improved 1-year graft survival and function in ECD kidneys. (Current Controlled Trials number: ISRCTN83876362).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Machine perfusion versus cold storage for the preservation of kidneys donated after cardiac death: a multicenter, randomized, controlled trial.

OBJECTIVE Hypothermic machine perfusion may improve outcome after transplantation of kidneys donated after cardiac death (DCD), but no sufficiently powered prospective studies have been reported. Because organ shortage has led to an increased use of DCD kidneys, we aimed to compare hypothermic machine perfusion with the current standard of static cold storage preservation. METHODS Eighty-two ...

متن کامل

Machine Perfusion versus Cold Storage of Kidneys Derived from Donation after Cardiac Death: A Meta-Analysis

BACKGROUND In response to the increased organ shortage, organs derived from donation after cardiac death (DCD) donors are becoming an acceptable option once again for clinical use in transplantation. However, transplant outcomes in cases where DCD organs are used are not as favorable as those from donation after brain death or living donors. Different methods of organ preservation are a key fac...

متن کامل

Machine perfusion versus cold storage for the preservation of kidneys from donors ≥ 65 years allocated in the Eurotransplant Senior Programme.

BACKGROUND In the Eurotransplant Senior Programme (ESP), kidneys from donors aged ≥ 65 years are preferentially allocated locally and transplanted into patients aged ≥ 65 years on dialysis. The purpose of this study was to analyse whether the results of transplantation in the ESP can be improved by preservation of organs by hypothermic machine perfusion (MP) compared with simple cold storage (C...

متن کامل

The cost-effectiveness of organ preservation methods in renal transplantation: US projections based on the machine preservation trial.

INTRODUCTION The European Machine Preservation Trial (MPT) found a significantly lower rate of delayed graft function and improved graft survival in machine-perfused kidneys compared to cold-stored kidneys in the first year following kidney transplantation. Little is known about the cost-effectiveness of various organ preservation methods. METHODS Outcome data from the MPT have been used to c...

متن کامل

Does machine perfusion decrease ischemia reperfusion injury?

In 1990's, use of machine perfusion for organ preservation has been abandoned because of improvement of preservation solutions, efficient without perfusion, easy to use and cheaper. Since the last 15 years, a renewed interest for machine perfusion emerged based on studies performed on preclinical model and seems to make consensus in case of expanded criteria donors or deceased after cardiac dea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transplant international : official journal of the European Society for Organ Transplantation

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2011