Needle-based ablation of renal parenchyma using microwave, cryoablation, impedance- and temperature-based monopolar and bipolar radiofrequency, and liquid and gel chemoablation: laboratory studies and review of the literature.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Small renal tumors are often serendipitously detected during the screening of patients for renal or other disease entities. Rather than perform a radical or partial nephrectomy for these diminutive lesions, several centers have begun to explore a variety of ablative energy sources that could be applied directly via a percutaneously placed needle-like probe. To evaluate the utility of such treatment for small renal tumors/masses, we compared the feasibility, regularity (consistency in size and shape), and reproducibility of necrosis produced in normal porcine kidneys by different modes of tissue ablation: microwaves, cold impedance-based and temperature-based radiofrequency (RF) energy (monopolar and bipolar), and chemical. Chemoablation was accomplished using ethanol gel, hypertonic saline gel, and acetic acid gel either alone or with simultaneous application of monopolar or bipolar RF energy. MATERIALS AND METHODS A total of 107 renal lesions were created laparoscopically in 33 domestic pigs. Microwave thermoablation (N=12) was done using a Targis T3 (Urologix) 10F antenna. Cryoablation (N=16) was done using a single 1.5-mm probe or three 17F microprobes (17F SeedNet system; Galil Medical) (N=10 single probe and N=6 three probes); a double freeze cycle with a passive thaw was employed under ultrasound guidance. Dry RF lesions were created using custom-made 18-gauge single-needle monopolar probe with two or three exposed metal tips (GelTx) (N=12) or a single-needle bipolar probe (N=6) at 50 W of 510 kHz RF energy for 5 minutes. In addition, a multitine RF probe (RITA Medical Systems) was used in one set of studies (N=6). Both impedance- and temperature-based RF were evaluated. Chemoablation was performed with 95% ethanol (4 mL), 24% hypertonic saline (4 mL), and 50% acetic acid (4 mL) as single injections. In addition, chemoablation was tested with monopolar and bipolar RF (wet RF). Tissues were harvested 1 week after ablation for light microscopy. RESULTS In 11 of the 15 ablation techniques, there was complete necrosis in all lesions; however, three ethanol gel lesions had skip areas, three hypertonic saline gel lesions showed no necrosis or injury, and one monopolar RF and one bipolar RF lesion showed skip areas. In contrast to impedance-based RF, heat-based RF (RITA) caused complete necrosis without skip areas. All cryolesions resulted in complete tissue necrosis, and cryotherapy was the only modality for which lesion size could be effectively monitored using ultrasound imaging. CONCLUSIONS Cryoablation and thermotherapy produce well-delineated, completely necrotic renal lesions. The single-probe monopolar and bipolar RF produce limited areas of tissue necrosis; however, both are enhanced by using hypertonic saline, acetic acid, or ethanol gel. Hypertonic saline gel with RF consistently provided the largest lesions. Ethanol and hypertonic saline gels tested alone failed to produce consistent cellular necrosis at 1 week. In contrast, RITA using the Starburst XL probe produced consistent necrosis, while impedance-based RF left skip areas of viable tissue. Renal cryotherapy under ultrasound surveillance produced hypoechoic lesions, which could be reasonably monitored, while all other modalities yielded hyperechoic lesions the margins of which could not be properly monitored with ultrasound imaging.
منابع مشابه
A Comparative Experimental Study of the In-vitro Efficiency of Hypertonic Saline-Enhanced Hepatic Bipolar and Monopolar Radiofrequency Ablation
OBJECTIVE To compare the in-vitro efficiency of a hypertonic saline (HS)-enhanced bipolar radiofrequency (RF) system with monopolar RF applications by assessing the temperature profile and dimensions of RF-created coagulation necrosis in bovine liver. MATERIALS AND METHODS A total of 27 ablations were performed in explanted bovine livers. After placement of two 16-gauge open-perfused electrod...
متن کاملAn Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation
Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...
متن کاملSaline-Enhanced Hepatic Radiofrequency Ablation Using a Perfused-Cooled Electrode: Comparison of Dual Probe Bipolar Mode with Monopolar and Single Probe Bipolar Modes
OBJECTIVE To determine whether saline-enhanced dual probe bipolar radiofrequency ablation (RFA) using perfused-cooled electrodes shows better in-vitro efficiency than monopolar or single probe bipolar RFA in creating larger coagulation necrosis. MATERIALS AND METHODS RF was applied to excised bovine livers in both bipolar and monopolar modes using a 200 W generator (CC-3; Radionics) and the p...
متن کاملHeat Sink Effect on Tumor Ablation Characteristics as Observed in Monopolar Radiofrequency, Bipolar Radiofrequency, and Microwave, Using Ex Vivo Calf Liver Model
Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices.With a perfused calf liver, the ablative performances (volume, mass, density, dimensions...
متن کاملBipolar radiofrequency ablation of the kidney: comparison with monopolar radiofrequency ablation.
PURPOSE We report initial ex vivo and in vivo studies using bipolar radiofrequency (RF) ablation of porcine kidneys. An internal ground electrode is positioned in the kidney opposite the RF electrode, resulting in ablation of all the intervening renal tissue. MATERIALS AND METHODS Ex vivo preparations of 10 porcine kidneys were perfused continuously with Ringer's solution and treated with eit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endourology
دوره 18 1 شماره
صفحات -
تاریخ انتشار 2004