The usefulness of intraoperative neurophysiological monitoring in cervical spine surgery: a retrospective analysis of 200 consecutive patients.

نویسندگان

  • Fenghua Li
  • Reza Gorji
  • Geoffrey Allott
  • Katharina Modes
  • Robert Lunn
  • Zhong-Jin Yang
چکیده

The usefulness of intraoperative neurophysiological monitoring (IONM), including somatosensory-evoked potential (SSEP) and transcranial electrical motor-evoked potentials (TcMEPs) in cervical spine surgery still needs to be evaluated. We retrospectively reviewed 200 cervical spine surgery patients from 2008 to 2009 to determine the role of IONM in cervical spine surgery. Total intravenous anesthesia was used for all patients. IONM alerts were defined as a 50% decrease in amplitude, a 10% increase in latency, or a unilateral change for SSEP and an increase in stimulation threshold of more than 100 V for TcMEP. Three patients had SSEP alerts that were related to arm malposition (2 patients) and hypotension (1 patient). Five patients had TcMEP alerts: 4 alerts were caused by hypotension and 1 by bone graft compression of the spinal cord. All alerts were resolved when causative reasons were corrected. There was no postoperative iatrogenic neurological injury. The sensitivities of SSEP and TcMEP alerts for detecting impending neurological injury were 37.5% and 62.5%, respectively. The sensitivity of both SSEP and TcMEP used in combination was 100%. No false-positive and false-negative alerts were identified in either SSEP or TcMEP (100% specificity). The total intravenous anesthesia technique optimizes the detection of SSEP and TcMEP and therefore improves the sensitivity and specificity of IONM. SSEP is sensitive in detecting alerts in possible malposition-induced ischemia or brachial plexus nerve injury. TcMEP specifically detects hypotension-induced spinal functional compromises. Combination use of TcMEP and SSEP enhances the early detection of impeding neurological damage during cervical spine surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can intraoperative neurophysiologic monitoring during cervical spine decompression predict post-operative segmental C5 palsy?

BACKGROUND C5 nerve root palsy is a known complication after cervical laminectomy or laminoplasty, characterized by weakness of the deltoid and bicep brachii muscles. The efficacy of intraoperative monitoring of these muscles is currently unclear. In the current prospective study, intraoperative monitoring through somatosensory (SSEPs), motor (TcMEPs) evoked potentials and real-time electromyog...

متن کامل

Bilateral C5 Palsy Following a Circumferential Surgery for Cervical Spondylotic Myelopathy: Case Report and Review (In press)

Background and Importance: The development of C5 root palsy is a well-known potential complication of cervical spine surgeries for the correction of cervical spondylotic myelopathy. It typically occurs unilaterally but on extremely rare occasions it might occur as a bilateral anomaly. The value of intraoperative neurophysiologic monitoring in detection of iatrogenic acute versus delayed onset C...

متن کامل

Neurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion.

BACKGROUND CONTEXT Somatosensory evoked potentials (SSEPs) monitor global spinal cord function, and the interpretation of motor loss is based on inferred rather than direct measurements. Therefore, SSEPs may not be useful for identifying motor function deficits caused by anterior spinal column injury or nerve root injury during decompression or placement of instrumentation. For these reasons, a...

متن کامل

The Utility of Somatosensory Evoked Potential Monitoring During Cervical Spine Surgery: How Often Does It Prompt Intervention and Affect Outcome?

STUDY DESIGN Retrospective review of the results of somatosensory evoked potentials (SSEP) performed in cervical spine surgery. PURPOSE To evaluate the utility of spinal cord monitoring during cervical spine surgery in a single surgeon's practice, based on how often it prompted an intraoperative intervention. OVERVIEW OF LITERATURE Intraoperative monitoring during cervical spine surgery is ...

متن کامل

Intraoperative somatosensory evoked potential monitoring during anterior cervical discectomy and fusion in nonmyelopathic patients--a review of 1,039 cases.

BACKGROUND CONTEXT Intraoperative somatosensory evoked potential (SSEP) monitoring has been shown to reduce the incidence of new postoperative neurological deficits in scoliosis surgery. However, its usefulness during cervical spine surgery remains a subject of debate. PURPOSE To determine the utility of intraoperative SSEP monitoring in a specific patient population (those with cervical radi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurosurgical anesthesiology

دوره 24 3  شماره 

صفحات  -

تاریخ انتشار 2012