Determinants of stroke volume and systolic and diastolic aortic pressure.

نویسندگان

  • N Stergiopulos
  • J J Meister
  • N Westerhof
چکیده

We investigated how parameters describing the heart and the arterial system contribute to the systolic and diastolic pressures (Ps and Pd, respectively) and stroke volume (SV). We have described the heart by the varying-elastance model with six parameters and the systemic arterial tree by the three-element windkessel model, leading to a total of nine parameters. Application of dimensional analysis led to a total of six dimensionless parameters describing dimensionless Ps and Pd, i.e., pressures with respect to venous pressure (Ps/Pv and Pd/Pv). SV was normalized with respect to unloaded ventricular volume (Vd). Sensitivity analysis showed that Ps/Pv, Pd/Pv, and SV/Vd could be accurately described by four, three, and three dimensionless parameters, respectively. With this limited number of parameters, it was then possible to obtain empirical analytical expressions for Ps/Pv, Pd/Pv, and SV/Vd. The analytic predictions were tested against the model values and found to be as follows: Ps predicted = (1.0007 +/- 0.0062) Ps, r = 0.987; Pd predicted = (1.016 +/- 0.0085) Pd, r = 0.992; and SV predicted = (0.9987 +/- 0.0028) SV, r = 0.996. We conclude that aortic Ps, Pd, and SV can be accurately described by a limited number of parameters and that, for any condition of the heart and the arterial system, Ps, Pd, and SV can be presented in analytical form.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diastolic aortic pressure rise during percutaneous transluminal coronary angioplasty: an index of left ventricular systolic dysfunction.

OBJECTIVES To investigate the relation between diastolic aortic pressure response and left ventricular systolic dysfunction during percutaneous transluminal coronary angioplasty. BACKGROUND The abnormal diastolic blood pressure rise during exercise in patients with coronary artery disease probably reflects left ventricular systolic dysfunction rather than the number of stenosed coronary arter...

متن کامل

Continuous determination of beat to beat stroke volume from aortic pressure pulses in the dog.

Present methods for measurement of stroke volume from the aortic pressure pulse are not suitable for beat-to-beat determinations during non-steady state conditions because these methods assume that each systolic ejection is equal to the peripheral runoff during the same beat. We have tested a new method which allows determination of an aortic pressure-volume conversion factor over a wide range ...

متن کامل

The use of angiotensin in the assessment of left ventricular function in fixed orifice aortic stenosis.

Catheterization of the left heart permits sophisticated assessment of the mechanical problem in aortic stenosis. Selection of patients for surgical repair requires an additional judgment regarding the contractile state of the left ventricle. Angiotensin has recently been used to study the function of the unobstructed left ventricle by imposing controlled pressure loads on both compensated and f...

متن کامل

Hemodynamic determinants of the maximal rate of rise of left ventricular pressure.

WALLACE, ANDREW G., N. SHELDON SKINNER, JR., AND JERE H. MITCHELL. Hemodynamic determinants of the maximal rate of rise of left ventricular pressure. Am, J. Physiol. 205 (I) : 30-36. 1963. -The maximal rate of left ventricular pressure development (max. dp/dt) was measured in an arenexic preparation which permitted independent control of stroke volume, heart rate, and aortic pressure. Max. dp/d...

متن کامل

تأثیر ماساژ بازتابی پا بر فشارخون بیماران مبتلا به سکته مغزی

  Background & Aim: Vascular events and strokes are third leading causes of death worldwide. There are also major causes of human morbidity. Various pharmacological and non-pharmacological treatments are proposed to patients with stroke. The purpose of this study was to determine effect of foot reflexology, as a non-pharmacological procedure, on systolic and diastolic blood pressures in patient...

متن کامل

Modified heart-lung preparation for the evaluation of systolic and diastolic coronary flow in rats.

A modified heart-lung preparation of the rat, which permits measuring systolic and diastolic coronary flow separately and enables coronary compliance to be evaluated, is described. The systemic circulation was substituted by a shunt circuit, and the elastic properties of the arterial tree were mimicked by a rubber balloon. Systolic and diastolic coronary flow was evaluated from the pulmonary an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of physiology

دوره 270 6 Pt 2  شماره 

صفحات  -

تاریخ انتشار 1996