Partial Discharge of Needle-Plane Defect in Oil-Paper Insulation under AC and DC Combined Voltages: Developing Processes and Characteristics
نویسندگان
چکیده
Partial discharge (PD) behaviors of oil-paper insulation is distinctive in AC and DC combined electric fields in converter transformers from PD behaviors in pure AC or DC electric fields. The present study focuses on the PD developing processes and characteristics of oil-paper insulation systems with needle-plane defects under different AC/DC proportions. The degradation of oil-paper insulation can be accelerated by PD pulses incurred by needle-plane defects. AC-DC combined voltages are applied to the needle-plane defect model simultaneously in the established experimental platform, and the proportions of AC/DC voltages are decided according to the cases in actual converter transformers. The developing processes from the initiation of partial discharge until final breakdown were observed for each AC/DC proportion. PD parameters and patterns were acquired by a detector using the pulse current method. The test results indicate that the inception and breakdown voltages increase with the increase of the DC component in AC-DC combined voltages. However, pulse repetition rate and amplitude of PD shows a descending trend when AC/DC proportion decreases. Meanwhile, the PD recurrence rate in the phase between 180◦ and 360◦ becomes higher than that in the phase between 0◦ and 180◦ at the initial stage as the DC proportion increases; high-amplitude discharges mainly occur in the phase range between 180◦ and 360◦ when the pressboard is close to breakdown. The current study is useful in further research on fault diagnosis in converter transformers.
منابع مشابه
Understanding the Discharge Activities in Transformer Oil under AC and DC Voltage Adopting UHF Technique
Design of Converter transformer insulation is a major challenge. The insulation of these transformers is stressed by both AC and DC voltages. Particle contamination is one of the major problems in insulation structures, as they generate partial discharges leading it to major failure of insulation. Similarly corona discharges occur in transformer insulation. This partial discharge due to particl...
متن کاملMeasurement and Analysis of Acoustic Signal Generated by Partial Discharges in Insulation Oil
This paper described the measurement of acoustic signal generated by partial discharge in insulation oil and analysis of their frequency spectrum to acquire information for diagnosing oil insulated transformers. We designed a decoupler and a low-noise amplifier to detect acoustic signals with high sensitivity. Also, three types of electrode system; the needle-plane, the plane-plane, the wire-wi...
متن کاملAcoustic Detection of Partial Discharges in Insulation Oil
In this paper, we performed an insulation diagnosis technique for oil-immersed power transformers by an acoustic detection method. Electrode system such as needle to plane electrode was fabricated to simulate a defect of power transformers. In addition, the frequency spectrum of acoustic signals with partial discharge (PD) in insulating oil was analyzed. From the FFT result, the frequency spect...
متن کاملStudy on the Characteristic Decomposition Components of DC SF6-Insulated Equipment under Positive DC Partial Discharge
Pulses with different amplitudes occur when an inner partial discharge fault exists in SF6-gas-insulated DC high-voltage electrical equipment. SF6 decomposes following complex physical and chemical processes. Discussing and quantifying the mathematical relationship of pulse discharge quantities to SF6 decomposition component characteristics is helpful to evaluate and predict the insulation faul...
متن کاملNew Fault-Tolerant Majority Gate for Quantum Dots Cellular Automata
In the high voltage (HV) electrical power systems, different materials are used as the role of insul ation to protect the incipient failure inside the HV power equipments. One of the common phenomenas in insulations is Partial Discharge (PD). Because of the high voltage stress, the weak section i nside the insulator causes the partial discharge (PD), which is known as a local electrical breakdo...
متن کامل