Non-invasive programmed stimulation to identify high-risk patients with implanted cardioverter defibrillator (the NIPS-ICD study): study protocol for a randomized controlled trial
نویسندگان
چکیده
BACKGROUND The use of an implantable cardioverter defibrillator (ICD) is a widely used and effective therapy, which reduces the risk of cardiac death in many cardiac diseases, both implanted for secondary and primary prevention. However, recurrent arrhythmias and ICD discharges have adverse prognostic significance. Additional parameters that would identify patients who are at increased risk of arrhythmias and appropriate ICD interventions would be of clinical value. Modern ICDs are relatively complex devices with a number of functions, including the possibility to perform noninvasive programmed stimulation (NIPS) with an implanted electrode located in the right ventricle. METHODS/DESIGN The aim of the study is to evaluate the usefulness of NIPS in determining the likelihood of life-threatening arrhythmic events in patients with ICD. The study will include 150 consecutive patients with an ICD implanted both for primary and secondary prevention, regardless of etiology, who are followed in the outpatient clinic of our center and do not meet the exclusion criteria. A 12-step St. George's Hospital NIPS protocol using ICD will be performed. The endpoint is to induce sustained ventricular arrhythmia (VT lasting more than 30 seconds or hemodynamically unstable VT/VF) or the end of the protocol. In case of serious and/or hemodynamically unstable heart rhythm disorders resistant to treatment with a low-energy antiarrhythmic pacing (ATP), the patient receives a short-term intravenous general anesthesia, and internal or external defibrillation is performed. Outpatient follow-up will be conducted during the pre-scheduled ICD control visits. An analysis of records of a registered memory device will be collected, a patient will be interviewed, and physical examination will be carried out. The follow-ups will be held every 3 months for 1 year. The primary endpoint of the follow-up will be appropriate intervention of ICD or sudden cardiac (arrhythmic) death; the secondary, appropriate ICD intervention, or death from cardiovascular causes; and the tertiary, appropriate ICD intervention, death or hospitalization for cardiovascular causes. DISCUSSION It is expected that appropriate ICD interventions during follow-up will occur more often in patients who had sustained ventricular arrhythmias induced during NIPS. CLINICAL TRIALS REGISTRY ClinicalTrials.gov, NCT02373306 , date of registration: 26 February 2015.
منابع مشابه
Novel ICD Programming and Inappropriate ICD Therapy in CRT-D Versus ICD Patients: A MADIT-RIT Sub-Study.
BACKGROUND The Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate therapy (MADIT-RIT) trial showed a significant reduction in inappropriate implantable cardioverter defibrillator (ICD) therapy in patients programmed to high-rate cut-off (Arm B) or delayed ventricular tachycardia therapy (Arm C), compared with conventional programming (Arm A). There is limited data on th...
متن کامل[Non-invasive electrophysiologic study and radiofrequency current ablation of tachycardia responsible for numerous inappropriate ICD interventions in patient with post-infarction dilated cardiomyopathy].
We present a case of 75-year-old man with numerous inappropriate interventions of an implanted cardioverter-defibrillator (ICD). In this patient with ischaemic cardiomyopathy, ICD was implanted for primary prevention of sudden cardiac death following recurrent syncope. ICD interrogation and non-invasive electrophysiologic study (NIPS) confirmed a risk of reentry-mediated tachycardia and exclude...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملRationale, objectives, and design of the EUTrigTreat clinical study: a prospective observational study for arrhythmia risk stratification and assessment of interrelationships among repolarization markers and genotype
AIMS The EUTrigTreat clinical study has been designed as a prospective multicentre observational study and aims to (i) risk stratify patients with an implantable cardioverter defibrillator (ICD) for mortality and shock risk using multiple novel and established risk markers, (ii) explore a link between repolarization biomarkers and genetics of ion (Ca(2+), Na(+), K(+)) metabolism, (iii) compare ...
متن کاملThe effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)
Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2016