TG‐51: Experience from 150 institutions, common errors, and helpful hints
نویسندگان
چکیده
The Radiological Physics Center (RPC) is a resource to the medical physics community for assistance regarding dosimetry procedures. Since the publication of the AAPM TG-51 calibration protocol, the RPC has responded to numerous phone calls raising questions and describing areas in the protocol where physicists have had problems. At the beginning of the year 2000, the RPC requested that institutions participating in national clinical trials provide the change in measured beam output resulting from the conversion from the TG-21 protocol to TG-51. So far, the RPC has received the requested data from approximately 150 of the approximately 1300 institutions in the RPC program. The RPC also undertook a comparison of TG-21 and TG-51 and determined the expected change in beam calibration for ion chambers in common use, and for the range of photon and electron beam energies used clinically. Analysis of these data revealed two significant outcomes: (i) a large number (approximately 1/2) of the reported calibration changes for photon and electron beams were outside the RPC's expected values, and (ii) the discrepancies in the reported versus the expected dose changes were as large as 8%. Numerous factors were determined to have contributed to these deviations. The most significant factors involved the use of plane-parallel chambers, the mixing of phantom materials and chambers between the two protocols, and the inconsistent use of depth-dose factors for transfer of dose from the measurement depth to the depth of dose maximum. In response to these observations, the RPC has identified a number of circumstances in which physicists might have difficulty with the protocol, including concerns related to electron calibration at low energies (R50<2 cm), and the use of a cylindrical chamber at 6 MeV electrons. In addition, helpful quantitative hints are presented, including the effect of the prescribed lead filter for photon energy measurements, the impact of shifting the chamber depth for photon depth-dose measurements, and the impact of updated stopping-power data used in TG-51 versus that used in TG-21, particularly for electron calibrations.
منابع مشابه
Nursing errors and effect on health care: Perception of risk factors from view of nurse in Qazvin
Background and aims: In order to plan for preventing and decreasing the rate of nursing errors, understanding of nurse’s perception of nursing errors could be very helpful. This study was thus designed to examine the critical care nurses perception of nursing errors from view point of critical care nurses. Methods: This study was conducted in 9 hospitals in Qazvin province located in north of ...
متن کاملConservative Bone Cuts and Technical Hints Incruciate Retaining Total Knee Arthroplasty, a 20 Years Experience
Total knee arthroplasty (TKA) is one of the most successful procedures in modern orthopedic surgery, providing high patient satisfaction rate. As a result, the number of patients undergoing TKA is increasing in number every year and more patients would be inclined to have the operation in near future . The demand for TKA is expected to grow 673% between 2005 and 2030. Knee surgeons are using mo...
متن کاملFeedback on Academic Essay Writing through pre-Emptive Hints: Moving Towards ”Advice for Action”
This paper adopts an “advice for action” approach to feedback in educational practice: addressing how provision of “hints” to participants before they write academic essays can support their understanding and performance in essay-writing tasks. We explored differences in performance by type of hint, and whether there was a transfer of better performance in subsequent essays. Fifty participants ...
متن کاملAccuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...
متن کاملHints: Is It Better to Give or Wait to Be Asked?
Many tutoring systems allow students to ask for hints when they need help solving problems, and this has been shown to be helpful. However, many students have trouble knowing when to ask for help or they prefer to guess rather than ask for and read a hint. Is it better to give a hint when a student makes an error or wait until the student asks for a hint? This paper describes a study that compa...
متن کامل