The effect of force, timing, and location on bone-to-implant contact of miniscrew implants.
نویسندگان
چکیده
This study was conducted to evaluate the effect of timing and force of loading, as well as implant location, on bone-to-implant contact (BIC) of loaded and control miniscrew implants (MSI). Using seven skeletally mature male beagle dogs, 1-2 years of age, followed over a 110 day period, a randomized split-mouth design compared immediate versus delayed loading, 50 versus 25 g loading, and 25 g loads in the maxilla versus the mandible. Mobility was evaluated using a 0-3 point scale before the MSIs were prepared for histological analysis. Histomorphometric analyses were performed under light microscopy using Metamorph software on undecalcified sections. The percentage BIC was measured at three levels (coronal, middle, and apical) of the MSI. BIC was compared statistically using pairwise Wilcoxon signed-rank tests. Mobility was detected in three of the 56 (5.4 per cent) MSIs. The mobile implants were all unloaded controls and showed no BIC. All remaining stable MSIs showed some BIC. However, variation in BIC was large, ranging from 2.2 to 100 per cent. There were no significant (P > 0.05) differences in BIC associated with timing of force application, amount of force applied, or implant location. There was a tendency for less BIC at the coronal level, but the differences between levels were not statistically significant. Within the limits of this study, it is concluded that the timing and amount of force at loading and location of implant placement do not affect BIC. Moreover, it appears that only limited amounts of osseointegration are necessary to ensure implant stability.
منابع مشابه
Effect of force on alveolar bone surrounding miniscrew implants: a 3-dimensional microcomputed tomography study.
INTRODUCTION The primary aim of this study was to better understand how bone adapts to forces applied to miniscrew implants. A secondary aim was to determine whether the direction of force applied to miniscrew implants has an effect on bone surrounding the miniscrew implants. METHODS A randomized split-mouth design, applied to 6 skeletally mature male foxhound dogs, was used to compare minisc...
متن کاملEffect of immediate loading on the biomechanical properties of bone surrounding the miniscrew implants.
The aim of this study was to investigate the effect of immediate loading on the biomechanical properties of bone surrounding a miniscrew implant. Forty titanium alloy miniscrew implants were placed on the buccal side of the maxillae and mandibles in four beagle dogs. Twelve pairs of miniscrew implants were immediately loaded with approximately 150 g of continuous force using nickel-titanium coi...
متن کاملمقایسه شاخصهای سلامتی لثه در افراد دریافت کننده ایمپلنتهای دندانی سیگاری و غیرسیگاری
Background : Although factors such as implant length, location, and diameter as well as bone quality have been associated with excessive failure rates, smoking is suggested as a stronger predisposing factor for higher failure rates. Thus, knowing the relationship between bone loss around the dental implants, maintenance of the implants and smoking could be a principle step towards solving the...
متن کاملRadiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study
Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...
متن کاملتحلیل پایداری ایمپلنت دندانی و بررسی تاثیر عوامل موثر بر اتصال ایمپلنت- استخوان به کمک مدل اصطکاکی تماس
Background and Aims: Relative displacement of the implant with respect to bone and quality of bone-implant contact play critical roles in the dental implant stability. The goal of this study was to investigate the dental implant stability using non-linear finite elements method. Therefore, bone-implant relative displacement due to applied force to the implant was calculated, and then an appropr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of orthodontics
دوره 31 3 شماره
صفحات -
تاریخ انتشار 2009