Dynamic Tracking of Joint Motion with Antagonized Smart Braids

نویسندگان

  • Wyatt Felt
  • Khai Yi Chin
  • C David Remy
چکیده

Our lab has developed a way to measure the contraction of Pneumatic Artificial Muscles (PAMs) using the reinforcing fibers themselves as sensing elements. We achieve this by using electrically-conductive wire to form the fiber braid. The inductance of this “Smart Braid” increases as the actuator contracts. We are interested in using these sensors for the feedback control of fluid systems that rely on PAM actuators. Toward that end, we have begun to explore highly portable inductance measurement techniques. Here, we demonstrate the forcecompensated tracking of a rotary joint angle at 1 kHz. This is an important step towards the utilization of these sensors in feedback control systems. Introduction McKibben Muscles are a common and popular type of soft, fluid-powered actuator due to their force dense, lightweight, and compliant features [1]. When pressurized fluid enters these “muscles” they expand radially while contracting longitudinally. It would be nice to use these actuators without rigid joints. However, the absence of rigid joints becomes a challenge for feedback control. Traditional sensors rely on a fixed datum point to perform tracking accurately. Some systems, like the trunk-like OctArm robot, use string potentiometers to determine the trunk tip position [2]. While these sensors provided sufficient shape sensing, the strings become a liability in harsh or high friction environments. We have developed a way to characterize the contraction of McKibben artificial muscles by using the braid as a sensor [3,4]. The braid of the muscle is made with insulated wires that form a single circuit. The inductance of this circuit corresponds to different braid lengths. We will present on our work to use these self-sensing actuators to track the motion of a joint driven by antagonized McKibben muscles (Fig. 1). We compare the joint angles predicted by the inductance measurements to joint angles measured with a potentiometer. Figure 1: The Smart Braid actuators that drive the joint can also measure its motion through the inductance measurements of the braids. Theory Inductance: The long solenoid equation provides an intuitive understanding of the relationship of the inductance to the braid length and cross sectional area. In this approximation, the inductance L is proportional to the cross sectional area A and inversely proportional to the braid length l: L = μ 0 N2A l (1) Clockwise (CW) Actuator Counter-Clockwise (CCW) Actuator 2015 Fluid Power Innovation & Research Conference (FPIRC15) Research Presentation Extended Abstract Submission μo is the magnetic permeability of the core and N is the number of turns of the coil. As the Smart Braid decreases in length and increases in cross sectional area, the fibers start to align to each other. This causes an increase in inductance similar to a solenoid. Therefore, the inductance decreases when the muscle relaxes, while the inductance increases when the muscle contracts. Methods Inductance Sensing: The inductance measurements are taken with a TI-LDC1612 Inductance-to-Digital Converter, which is connected to a resonant circuit made up of the smart braid and a small capacitor in parallel [5]. By using a frequency counter, the TI-LDC1612 measures the circuit’s frequency of oscillation, fsensor. The sensor frequency is then used to determine the inductance of the smart braid, L, using the value of the capacitance, C: L = 1 C×(2π×fsensor) 2 (2) Calibration: To calibrate the Smart Braid sensor, we increased the pressure of a single actuator from 15-45 psi, with increments of 5 psi after every 30 seconds, while the antagonized actuator would be pressurized to attain a specified desired tension in the system. We do that for both actuators and measured the inductance at 1 kHz. Only the final 15 seconds of each 30second period were analyzed. The inductance measurements of each muscle were fit with a linear regression to the angle of the pulley as shown in Fig. 2. We also tested the antagonized actuators with various levels of tension. This allowed us to characterize both the force-pressure relationship of each actuator and the stiffness of the actuator connections. Figure 2: The calibration test was run with a specified tension of 2 lbs and the inductance measurement was collected at 1 kHz. The inductance had a linear relationship to the angle, which is proportional to the actuator length. 2015 Fluid Power Innovation & Research Conference (FPIRC15) Research Presentation Extended Abstract Submission Dynamic Tracking: Once the Smart Braid sensor was calibrated, we introduced perturbations to the system by manually pushing the lever arm attached to the pulley shaft with the actuators pressurized to 20 psi. The inductance measured was then used to compute the angle outputs, which was compared to the results of the potentiometer. The length of the each actuator was computed using inductance measurements collected at 1 kHz. Using the pressure measurements and the characterized, force-pressure relationship, we were able to estimate the tension in each actuator connection. With the estimated tension, we applied our model of the connection stiffness to compensate for the stretching in the actuator connections. We can then calculate the “force compensated” joint angle. Results and Discussion The result of the dynamic tracking experiment was compared to the calibrated data. As shown in Fig. 3, the angle predictions provided by both the CCW actuator and the CW actuator are not too far from the angle measured by the potentiometer. The actuator that is “slack” always significantly under-predicts the magnitude of the angle. By compensating for the stretching in the connections, the joint angle predictions improve for the actuator under tension. Figure 3: The force perturbation on the lever arm moved the pulley between -45 degrees and 30 degrees. The muscles were not inflated before 30 seconds, thus showing a difference in angle prediction between the actuators due to the slack in the rope connecting to the pulley. 2015 Fluid Power Innovation & Research Conference (FPIRC15) Research Presentation Extended Abstract Submission

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-Sensing Pneumatic Artificial Muscles for Feedback Control using the Inductance of “Smart Braids”

Measuring and controlling Pneumatic Artificial Muscles (PAMs) without instrumented, mechanical structures can be challenging. This is the case, for example, when the actuators are used in soft, human exosuits [5]. “Smart Braids” measure the length of PAMs through the inductance of a conductive braid. The inductance increases linearly with the contraction of the actuator. We have modeled and tes...

متن کامل

Multiple Target Tracking With a 2-D Radar Using the JPDAF Algorithm and Combined Motion Model

Multiple target tracking (MTT) is taken into account as one of the most important topics in tracking targets with radars. In this paper, the MTT problem is used for estimating the position of multiple targets when a 2-D radar is employed to gather measurements. To do so, the Joint Probabilistic Data Association Filter (JPDAF) approach is applied to tracking the position of multiple targets. To ...

متن کامل

A Joint System for Single-Person 2D-Face and 3D-Head Tracking in CHIL Seminars

We present the IBM systems submitted and evaluated within the CLEAR’06 evaluation campaign for the tasks of single person visual 3D tracking (localization) and 2D face tracking on CHIL seminar data. The two systems are significantly inter-connected to justify their presentation within a single paper as a joint vision system for single person 2D-face and 3D-head tracking, suitable for smart room...

متن کامل

Trajectory Tracking Weeled Mobile Robot Using Backstepping Method with Connection off Axle Trailer

The connection of the tractor to the inactive trailer or motor vehicle causes a motion control problem when turning in the screw, forward or backward movements and high speeds. This is due to the inactive trailer being controlled by the tracking using a physical link that is not affected by the movement. Trailers usually take tracks under these conditions. This phenomenon is called Jack Knife. ...

متن کامل

Dynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback

Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015