An accelerated clinical chairside technique for casting overdenture attachment copings.

نویسندگان

  • Michael D Scherer
  • Wayne V Campagni
چکیده

An accelerated technique for casting a direct-pattern post and core restoration for use in fixed prosthodontics has been previously described. Similar techniques for use in removable prosthodontics show potential for clinical use, specifically for the fabrication of radicular stud overdenture attachments and their corresponding copings. The procedure uses a chairside technique and readily available components to fabricate a direct, acrylic resin pattern combining the elements of a cast coping with a fixed radicular attachment. This pattern can subsequently be invested, cast, finished and polished, luted, and attached to the removable prosthesis in a single clinical appointment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Marginal accuracy of nickel chromium copings fabricated by conventional and accelerated casting procedures, produced with ringless and metal ring investment procedures: A comparative in vitro study.

BACKGROUND Conventional investing and casting techniques are time-consuming and usually requires 2-4 h for completion. Accelerated nonstandard, casting techniques have been reported to achieve similar quality results in significantly less time, namely, in 30-40 min. During casting, it is essential to achieve compensation for the shrinkage of solidifying alloy by investment expansion. The metal ...

متن کامل

Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient

Implant-supported overdenture is a reliable treatment option for the patients with edentulous mandible when they have difficulty in using complete dentures. Several options have been used for implant-supported overdenture attachments. Among these, bar attachment system has greater retention and better maintainability than others. SFI-Bar® is prefabricated and can be adjustable at chairside. The...

متن کامل

Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems

PURPOSE To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the catego...

متن کامل

Implant overdenture and Locator system in edentulous patient with severely resorbed mandible - a case report.

Clinical studies have revealed that the main objective of implants in the edentulous jaw is to provide support for fixed prostheses or to stabilize complete dentures. Various attachment systems were developed for universal use in partially and completely edentulous patients such as clasps, cone-shape telescope copings, magnets, bar systems, locators. The aim of this case report is to present th...

متن کامل

Specially Designed Copings for Stability of Overdentures

Aim: The aim of this study was to describe the process of fabrication of specially designed MCOP and define their function in improving of stability. Purpose: In many clinical situations, exposed dentin surfaces of abutment teeth were restored with metal copings prior to fabrication of the overdentures. The aim of this study was to examine a procedure for fabrication of specially designed metal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 106 5  شماره 

صفحات  -

تاریخ انتشار 2011