Fractional Exhaled Nitric Oxide: Comparison Between Portable Devices and Correlation With Sputum Eosinophils

نویسندگان

  • Sehyo Yune
  • Jin-Young Lee
  • Dong-Chull Choi
  • Byung-Jae Lee
چکیده

This study was performed to compare the 2 different portable devices measuring fractional exhaled nitric oxide (FeNO) and to see the correlation between FeNO and induced sputum eosinophil count (ISE). Forty consecutive subjects clinically suspected to have asthma underwent FeNO measurement by NIOX-MINO® and NObreath® concurrently. All also had induced sputum analysis, methacholine provocation test or bronchodilator response test, and spin prick test. Agreement between the 2 devices was evaluated. The correlation between FeNO and ISE was assessed, as well as the cut-off level of FeNO to identify ISE ≥3%. The intraclass correlation coefficient (ICC) between FeNO levels measured by NIOX-MINO® (FeNO(NIOX-MINO)) and NObreath® (FeNO(NObreath)) was 0.972 with 95% confidence interval of 0.948-0.985. The 95% limits of agreement were -28.9 to 19.9 ppb. The correlation coefficient between ISE and FeNO(NIOX-MINO) was 0.733 (P<0.001), and 0.751 between ISE and FeNO(NObreath) (P<0.001). The ROC curve found that the FeNO(NIOXMINO) of 37.5 ppb and the FeNO(NObreath) of 36.5 ppb identified ISE ≥3% with 90% sensitivity and 81% specificity. Age, sex, body mass index, smoking history, atopy, and the presence of asthma did not affect the FeNO level and its correlation with ISE. The NIOX-MINO ® and NObreath® agree with each other to a high degree. Both devices showed close correlation with ISE with similar cut-off value in identifying ISE ≥3%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between exhaled nitric oxide, sputum eosinophils, and methacholine responsiveness in patients with mild asthma.

BACKGROUND Eosinophils in induced sputum and exhaled nitric oxide (NO) are currently used as non-invasive markers in the assessment of airway inflammation in asthma. As both sputum eosinophils (%) and exhaled NO are raised in asthmatic subjects not receiving inhaled steroids and decreased following corticosteroid therapy, a relationship between them is plausible. METHODS Exhaled NO was measur...

متن کامل

Sputum eosinophils and exhaled nitric oxide during late asthmatic reaction in patients with western red cedar asthma.

Examination of sputum for eosinophils and measurement of exhaled nitric oxide have been proposed as noninvasive methods of assessing airway inflammation in asthma. The use of these tests in the evaluation of patients with occupational asthma has not been reported. This study investigated the changes in sputum eosinophils and exhaled NO before and at intervals after inhalation challenge with pli...

متن کامل

Exhaled nitric oxide and sputum eosinophil markers of inflammation in asthmatic children.

Exhaled nitric oxide and eosinophil sputum markers are considered noninvasive ways in which to evaluate airway inflammation in asthma. The aim of this study was to evaluate the relationships between these methods of evaluation in asthmatic children. In a cross-sectional study of 25 mild-moderate asthmatic children (aged 6-13 yrs, 10 patients on inhaled steroids) exhaled NO was measured along wi...

متن کامل

The Value of Induced Sputum in the Diagnosis and Management of Children with Bronchial Asthma

BACKGROUND Induced sputum in children with bronchial asthma represents a non-invasive method of bronchial inflammation assessment. The main objective of our study was to analyze the cellularity of sputum in patients with bronchial asthma according to the level of disease control and the controlling therapy (with/without inhaled glucocorticoids). The second objective was to establish the correla...

متن کامل

Cutoff point for exhaled nitric oxide corresponding to 3% sputum eosinophils.

BACKGROUND The eosinophilic asthma phenotype (sputum eosinophils 3%) indicates a good response to corticosteroids and T(H)2 immunomodulators. Exhaled nitric oxide (FeNO) is rapidly measured by portable devices, and although it is not a selective marker of eosinophilic inflammation, several studies have demonstrated a strong correlation with it. We investigated which FeNO value was the best fit ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015