The VITEK 2 is a new automated instrument for rapid organism identification and susceptibility testing. It has the capability of performing rapid susceptibility testing of Streptococcus pneumoniae with specially configured cards that contain enriched growth medium and antimicrobial agents relevant for this organism. The present study compared the results of testing of a group of 53 challenge strains of pneumococci with known resistance properties and a collection of clinical isolates examined in two study phases with a total of 402 and 416 isolates, respectively, with a prototype of the VITEK 2. Testing was conducted in three geographically separate laboratories; the challenge collection was tested by all three laboratories, and the unique clinical isolates were tested separately by the individual laboratories. The VITEK 2 results of tests with 10 antimicrobial agents were compared to the results generated by the National Committee for Clinical Laboratory Standards reference broth microdilution MIC test method. Excellent interlaboratory agreement was observed with the challenge strains. The overall agreement within a single twofold dilution of MICs defined by the VITEK 2 and reference method with the clinical isolates was 96.3%, although there were a number of off-scale MICs that could not be compared. The best agreement with the clinical isolates was achieved with ofloxacin and chloramphenicol (100%), and the lowest level of agreement among those drugs with sufficient on-scale MICs occurred with trimethoprim-sulfamethoxazole (89.7%). Overall there were 1.3% very major, 6.6% minor, and no major interpretive category errors encountered with the clinical isolates, although >80% of the minor interpretive errors involved only a single log(2) dilution difference. The mean time for generation of susceptibility results with the clinical isolates was 8.1 h. The VITEK 2 provided rapid, reliable susceptibility category determinations with both the challenge and clinical isolates examined in this study.
منابع مشابه
The Biomerieux Solution Did You Know? Practical Advice
We evaluated the accuracy of the VITEK 2 fully automated system to detect andidentify glycopeptide-resistant enterococci (GRE) compared to a reference agardilution method. The sensitivity of vancomycin susceptibility testing with VITEK 2for the detection of vanA, vanB, and vanC1 strains was 100%. The sensitivity ofvancomycin susceptibility testing of vanC2 strains was 77%. T...
متن کاملMeropenem resistance in imipenem-susceptible meropenem-resistant Klebsiella pneumoniae isolates not detected by rapid automated testing systems.
Klebsiella pneumoniae showing high resistance to all β-lactams except imipenem, designated as ISMRK (imipenem-susceptible meropenem-resistant Klebsiella) is emerging in Japan. The carbapenem resistance of ISMRK cannot be screened by the Vitek and the RAISUS rapid automated susceptibility test systems, which may lead to inappropriate antimicrobial therapy, resulting in compromised patient outcomes.
متن کاملSusceptibility Testing of Pseudomonas Aeruginosa by the Vitek 2 System: a Comparison with Etest Results. Susceptibility Testing of Pseudomonas Aeruginosa by the Vitek 2 System: a Comparison with Etest Results
P. aeruginona infections need accurate antimicrobial susceptibility data, as treatment mainly relies on antibiotic effi ciency in debilitated patients. Vitek 2, a popular automated susceptibility testing method, was compared with Etest to assess its reliability on 150 Belgian P. aeruginonas isolates. Vitek 2 and Etest exhibited a high degree of concordance, but some discrepancies in clinical ca...
متن کاملAntimicrobial susceptibility and analysis of macrolide resistance genes in Streptococcus pneumoniae isolated in Hamadan
Objective(s): Macrolide resistant Streptococcus pneumoniae pose an emerging problem globally. The aim of this study was to investigate the prevalence of ermB and mefA genes (macrolide resistant genes) by polymerase chain reaction (PCR) method and to detect drug resistance patterns of S. pneumoniae isolated from clinical samples to macrolides and other antibiotic agents by E-test method. Materia...
متن کاملPerformance Evaluation of a Newly Developed and Fully Automated Bacteriological Analyzer "RAISUS ANY" for Antimicrobial Susceptibility Testing of Fastidious Bacteria Haemophilus influenzae and Streptococcus pneumoniae.
OBJECTIVE Antimicrobial susceptibility testing for fastidious bacteria, such as Haemophilus influenzae (H. influenzae) and Streptococcus pneumoniae (S. pneumoniae) has been performed manually. We evaluated the performance of a newly developed fully automated system for rapid bacterial identification and antimicrobial susceptibility testing "RAISUS ANY" (Nissui Pharmaceutical Co., Ltd.). METHO...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 38 8 شماره
صفحات -
تاریخ انتشار 2000