Measurement of optic disc size: equivalence of methods to correct for ocular magnification.

نویسندگان

  • D F Garway-Heath
  • A R Rudnicka
  • T Lowe
  • P J Foster
  • F W Fitzke
  • R A Hitchings
چکیده

AIMS To compare methods available to correct the magnification of images that result from the optics of the eye and identify errors, and source of error, of the methods. METHODS 11 methods were applied to ocular biometry data from three independent cohorts. Each method was compared with the method of Bennett, which uses most biometric data. The difference between each method and Bennett's is the "error" of the method. The relation between the error and axial length, ametropia, and keratometry was explored by linear regression analysis. RESULTS Methods using axial length had the lowest mean (+0.5 to +2.6%) and standard deviation (0.6 to 1.2%) of errors. Of methods using keratometry and ametropia only, the lowest mean (-1.4% to +4.4%) and standard deviation (2.9 to 4.3%) of errors was found for a new method described in this paper, and that used by the Heidelberg retina tomograph (HRT). The highest mean error (+2.2 to +7.1%) was found for Littmann's method. Littmann's correction was larger than the HRT's by 3.5 to 3.7%. The mean difference between the new and HRT methods and the "abbreviated axial length" method of Bennett is -1.3 to +2.0%. The error of the "keratometry and ametropia" methods is related to axial length. CONCLUSIONS Methods using axial length are most accurate. The abbreviated axial length method of Bennett differs little from more detailed calculations and is appreciably more accurate than methods using keratometry and ametropia alone. If axial length is unknown, the new and the HRT methods give results closest to the abbreviated axial length method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Myopia on Size of Optic Nerve Head and Retinal Nerve Fiber Layer Thickness Measured by Spectral Domain Optical Coherence Tomography

PURPOSE To investigate optic nerve head size and retinal nerve fiber layer (RNFL) thickness according to refractive status and axial length. METHODS In a cross-sectional study, 252 eyes of 252 healthy volunteers underwent ocular biometry measurement as well as optic nerve head and RNFL imaging by spectral-domain optical coherence tomography. Correlation and linear regression analyses were per...

متن کامل

Magnification characteristic of a +90-diopter double-aspheric fundus examination lens.

PURPOSE To investigate the magnification characteristic of the +90-D double-aspheric fundus examination lens for biomicroscopic measurement of the optic disc. METHODS A calibrated Gullstrand-type model eye adjusted for axial ametropia between -12.5 and +12.6 D was used to measure the change in magnification of the system with refractive error and variation in fundus lens position. A correctio...

متن کامل

Neuroretinal rim width ratios in morphological glaucoma diagnosis.

AIMS To evaluate the inferior to temporal neuroretinal rim width ratio and superior to temporal rim width ratio as measures of rim shape for diagnosis of glaucoma. METHODS Colour stereo optic disc photographs of 527 normal subjects, 100 ocular hypertensive individuals with normal visual fields, and 202 open angle glaucoma patients with a mean perimetric defect of less than 10 dB were morphome...

متن کامل

Optic disc measurement with the Zeiss four mirror contact lens.

A knowledge of the optic disc size may be of value when assessing the glaucoma suspect. The vertical diameter of the optic disc was measured using a Zeiss four mirror gonioscope and a 900 Haag-Streit slit-lamp in one eye of 39 patients, 32 with refractive errors within 3 dioptres of emmetropia. The disc was measured by projecting a slit beam of known height onto the image of the disc. A magnifi...

متن کامل

Ranking of optic disc variables for detection of glaucomatous optic nerve damage.

PURPOSE To describe optic disc variables assessed by evaluation of clinical optic disc photographs and to compare sensitivity and specificity of these optic disc parameters in identifying patients with ocular hypertension who have nerve fiber layer defects and normal visual fields and patients with visual field defects. METHODS The study included 500 normal subjects, 132 patients with ocular ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 82 6  شماره 

صفحات  -

تاریخ انتشار 1998