Application of Semipermeable Membranes in Glucose Biosensing

نویسندگان

  • Tanmay Kulkarni
  • Gymama Slaughter
چکیده

Glucose biosensors have received significant attention in recent years due to the escalating mortality rate of diabetes mellitus. Although there is currently no cure for diabetes mellitus, individuals living with diabetes can lead a normal life by maintaining tight control of their blood glucose levels using glucose biosensors (e.g., glucometers). Current research in the field is focused on the optimization and improvement in the performance of glucose biosensors by employing a variety of glucose selective enzymes, mediators and semipermeable membranes to improve the electron transfer between the active center of the enzyme and the electrode substrate. Herein, we summarize the different semipermeable membranes used in the fabrication of the glucose biosensor, that result in improved biosensor sensitivity, selectivity, dynamic range, response time and stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Progresses in Preparation and Characterization of RO Membranes

Reverse osmosis (RO) is a water purifcation technology that uses a semipermeable membrane to remove ions, molecules, and larger particles for the production of drinking water. The frst RO membrane for seawater desalination, wastewater treatment and other applications were made of cellulose acetate. But, the polyamide thin-flm composite membrane that can tolerate wide pH...

متن کامل

Review on Graphene FET and its Application in Biosensing

Graphene, after its first production in 2004 have received lots of attentions from researchers because of its unique properties. High mobility, high sensitivity, high selectivity and high surface area make graphene excellent choice for bio application. One of promising graphene base device that has amazingly high sensitivity is graphene field-effect transistor (GFET). This review selectively su...

متن کامل

Membranes to achieve immunoprotection of transplanted islets.

Transplantation of islet or beta cells is seen as the cure for type 1 diabetes since it allows physiological regulation of blood glucose levels without requiring any compliance from the patients. In order to circumvent the use of immunosuppressive drugs (and their side effects), semipermeable membranes have been developed to encapsulate and immunoprotect transplanted cells. This review presents...

متن کامل

Microfabricated, amperometric, enzyme-based biosensors for in vivo applications

Miniaturized electrochemical in vivo biosensors allow the measurement of fast extracellular dynamics of neurotransmitter and energy metabolism directly in the tissue. Enzyme-based amperometric biosensing is characterized by high specificity and precision as well as high spatial and temporal resolution. Aside from glucose monitoring, many systems have been introduced mainly for application in th...

متن کامل

Amperometric Glucose Biosensors: Past, Present and Future

Foundations of biosensor and its technological advancements thereof, was laid down by father of the biosensor, Professor Leland C Clark Jnr., in 1956 with advent of Clark oxygen electrode. The first biosensor dates back to 1962, when Clark and Lyons of the Cincinnati Children’s Hospital proposed the first enzyme based electrode to measure blood glucose[26]. The underlying principle being monito...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016