Noninvasive assessment of the digital volume pulse. Comparison with the peripheral pressure pulse.

نویسندگان

  • S C Millasseau
  • F G Guigui
  • R P Kelly
  • K Prasad
  • J R Cockcroft
  • J M Ritter
  • P J Chowienczyk
چکیده

The digital volume pulse can be recorded simply and noninvasively by photoplethysmography. The objective of the present study was to determine whether a generalized transfer function can be used to relate the digital volume pulse to the peripheral pressure pulse and, hence, to determine whether both volume and pressure pulse waveforms are influenced by the same mechanism. The digital volume pulse was recorded by photoplethysmography in 60 subjects (10 women, aged 24 to 80 years), including 20 subjects with previously diagnosed hypertension. Simultaneous recordings of the peripheral radial pulse and digital artery pulse were obtained by applanation tonometry and a servocontrolled pressure cuff (Finapres), respectively. In 20 normotensive subjects, measurements were obtained after the administration of nitroglycerin (NTG, 500 microgram sublingually). Transfer functions obtained by Fourier analysis of the waveforms were similar in normotensive and hypertensive subjects. In normotensive subjects, transfer functions were similar before and after NTG. By use of a single generalized transfer function for all subjects, the radial and digital artery pressure waveforms could be predicted from the volume pulse with an average root mean square error of 4.4+/-2.0 and 4.3+/-1.9 mm Hg (mean+/-SD) for radial and digital artery waveforms, respectively, similar to the error between the 2 pressure waveforms (4.4+/-1.4 mm Hg). The peripheral pressure pulse is related to the digital volume pulse by a transfer function, which is not influenced by effects of hypertension or NTG. Effects of NTG on the volume pulse and pressure pulse are likely to be determined by a similar mechanism.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison With the Peripheral Pressure Pulse

The digital volume pulse can be recorded simply and noninvasively by photoplethysmography. The objective of the present study was to determine whether a generalized transfer function can be used to relate the digital volume pulse to the peripheral pressure pulse and, hence, to determine whether both volume and pressure pulse waveforms are influenced by the same mechanism. The digital volume pul...

متن کامل

تخمین بدون کاف فشارخون مبتنی بر ویژگی‌های زمانی سیگنال نبض

Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...

متن کامل

Contour analysis of the photoplethysmographic pulse measured at the finger.

Analysis of the contour of the peripheral pulse to assess arterial properties was first described in the nineteenth century. With the recognition of the importance of arterial stiffness there has been a resurgence of interest in pulse wave analysis, particularly the analysis of the radial pressure pulse acquired using a tonometer. An alternative technique utilizes a volume pulse. This may conve...

متن کامل

Pulse Wave Analysis Digital Plethysmography Finger Plethysmography Accelerated Plethysmography Clinical Bottom Line - The Simple Explanation

The digital plethysmograph is a secondary output of the pulse oximeter, which is commonly used to measure arterial blood saturation (SaO2)61. Digital plethysmography provides noninvasive, continuous, and real-time measurement of arterial pressure with infrared light transmitted through a digit (finger or toe)62. This technique acquires the digital volume pulse (DVP), a waveform that estimates p...

متن کامل

Respiratory Variations in Pulse Pressure Reflect Central Hypovolemia during Noninvasive Positive Pressure Ventilation

Background. Correct volume management is essential in patients with respiratory failure. We investigated the ability of respiratory variations in noninvasive pulse pressure (ΔPP), photoplethysmographic waveform amplitude (ΔPOP), and pleth variability index (PVI) to reflect hypovolemia during noninvasive positive pressure ventilation by inducing hypovolemia with progressive lower body negative p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 36 6  شماره 

صفحات  -

تاریخ انتشار 2000