History of instrumentation for stabilization of the subaxial cervical spine.

نویسندگان

  • Ibrahim Omeis
  • Joseph A DeMattia
  • Virany Huynh Hillard
  • Raj Murali
  • Kaushik Das
چکیده

In the past several decades methods have been developed to stabilize the subaxial cervical spine both posteriorly and anteriorly. Methods of posterior stabilization have progressed from interspinous wiring, through facet wiring and sublaminar wiring, to the lateral mass screws with plates and rods that are in use today. Plates for anterior stabilization have evolved from rigid plates requiring bicortical screws through those used with unicortical locking screws, to dynamic load-sharing plates used with variable angle screws. The original description of spinous process wiring was published by Hadra in 1891. In 1942 Rogers described the interspinous wiring method used for trauma-induced cervical instability, which was modified by Bohlman in 1985 (triple wiring technique). Luque rods with sublaminar wires were introduced in the late 1970s to address multilevel and occipitocervical instability. Facet wiring was developed in 1977 by Callahan to address the problem of stabilization when laminae are not present. Wiring remained the method used until Roy-Camille introduced the lateral mass screw-plate construct in the 1980s. The first plate for anterior stabilization was designed by Orozco and Llovet in 1970 and was later refined by Caspar; this was a rigid plate with bicortical screws. Morscher devised unicortical locking screws in the 1980s. The latest concept of dynamic load-sharing plates with variable angle screws was developed in 2000. In this article historical landmarks in surgical methods for the stabilization of the subaxial cervical spine are reviewed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bilateral Pedicle and Crossed Translaminar Screws in C2

Multiple techniques exist for the fixation of C2, including axial pedicle screws and bilateral translaminar screws. We describe a novel method of incorporating both the translaminar and pedicle screws within C2 to improve fixation to the subaxial spine in patients requiring posterior cervical instrumentation for deformity correction or instability. We report three cases of patients with cervica...

متن کامل

Posterior Cervical Pedicle Screw-Rod/Plate Instrumentation Combined with Unilateral Open-Door Laminoplasty for the Treatment of Acute Cervical Spinal Cord Compression Injury: Report of Five Cases.

All patients were acute, multi-segment cervical spinal cord compression injury secondary to subaxial cervical spine fracture. These patients underwent emergency posterior cervical pedicle screw-rod/plate instrumentation combined with unilateral open-door laminoplasty. Well-placed pedicle screws and good cervical canal dilation were achieved in all patients, as assessed by radiography. Patients ...

متن کامل

Axis Screw Fixation – A Step-by-Step Review of the Surgical Techniques

Fixation of the axis may be necessary in cases of atlantoaxial instability, secondary to different causes, such as congenital, trauma, neoplasm or inflammatory diseases.1 Additionally, the axis may be included in the spinal instrumentation procedure requiring occipitocervical stabilization or even extension of the subaxial cervical spine surgeries.1 The classic fixation of the atlantoaxial regi...

متن کامل

Anterior instrumentation for cervical spine tuberculosis: an analysis of surgical experience with 61 cases.

OBJECTIVE To evaluate the efficacy of anterior instrumentation in patients with subaxial and cervicodorsal spinal tuberculosis in reconstruction of the spine, providing pain relief, neurological recovery and prevention of deformity. MATERIALS AND METHODS The records of 61 consecutive patients, of surgically treated spinal tuberculosis affecting C3 to D2 region, in our neuro and spinal surgery...

متن کامل

Anatomic Study of Anterior Transdiscal Axial Screw Fixation for Subaxial Cervical Spine Injuries

Anterior transdiscal axial screw (ATAS) fixation is an alternative or supplement to the plate and screw constructs for the upper cervical spine injury. However, no existing literatures clarified the anatomic feasibility of this technique for subaxial cervical spine. Therefore, the objective of this study was to evaluate the anatomical feasibility and to establish guidelines for the use of the A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurosurgical focus

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2004