Very high-pressure dilatation for undilatable coronary lesions: indications and results with a new dedicated balloon.
نویسندگان
چکیده
AIMS Calcific coronary lesions impose a rigid obstacle to optimal balloon and stent expansion and the 20 to 30 atm limit that non-compliant (NC) balloons reach can be insufficient. The aim of our study was to evaluate the safety and efficacy of a new dedicated super high-pressure NC balloon (OPN NC®; SIS Medical AG, Winterthur, Switzerland). METHODS AND RESULTS We retrospectively evaluated a consecutive series of 91 lesions in which conventional NC balloons at maximal pressure failed to achieve an adequate post-dilatation luminal gain and were therefore treated with an OPN NC balloon up to 40 atm. Angiographic success was defined as residual angiographic diameter stenosis <30%. MLD and %DS were measured at baseline, after NC balloon, OPN NC balloon and stent implantation. Angiographic success was achieved in 84 lesions (92.3%). All of the remaining lesions received rotational atherectomy with the exception of two cases in which rotational atherectomy was not attempted because of small vessel size and excessive tortuosity. MLD and acute gain were significantly greater and %DS was significantly lower post OPN NC balloon compared with conventional NC balloon inflation (p<0.001). No coronary perforations occurred. No acute or 30-day follow-up MACE was reported. CONCLUSIONS When conventional NC balloons fail, the new OPN NC dedicated high-pressure balloon provides an effective and safe alternative strategy for the dilatation of resistant coronary lesions.
منابع مشابه
A noncompliant, high pressure balloon to manage undilatable coronary lesions.
Undilatable coronary lesions, due to coronary calcification, are encountered with increasing frequency. Percutaneous intervention of such lesions comes with the risk of stent underexpansion, which increases the risk of stent thrombosis and restenosis. A variety of techniques and devices are available to assist the interventionist in the treatment of calcified lesions. The OPN NC (SIS-Medical AG...
متن کاملRotational ablation assisted angioplasty of an obstructed aortopulmonary collateral artery.
A 15 month old baby girl with pulmonary atresia, ventricular septal defect, and multiple aortopulmonary collateral arteries underwent rotational ablation assisted balloon angioplasty of a severely stenosed collateral artery that had previously proved undilatable using a high pressure non-compliant balloon angioplasty catheter. It is postulated that the rotablation debulked a fibrotic stricture ...
متن کاملCASE REPORT Rotational ablation assisted angioplasty of an obstructed aortopulmonary collateral artery
A 15 month old baby girl with pulmonary atresia, ventricular septal defect, and multiple aortopulmonary collateral arteries underwent rotational ablation assisted balloon angioplasty of a severely stenosed collateral artery that had previously proved undilatable using a high pressure non-compliant balloon angioplasty catheter. It is postulated that the rotablation debulked a fibrotic stricture ...
متن کاملAdjunctive Strategies in the Management of Resistant, ‘Undilatable’ Coronary Lesions After Successfully Crossing a CTO with a Guidewire
Successful revascularisation of chronic total occlusions (CTOs) remains one of the greatest challenges in the era of contemporary percutaneous coronary intervention (PCI). Such lesions are encountered with increasing frequency in current clinical practice. A predictable increase in the future burden of CTO management can be anticipated given the ageing population, increased rates of renal failu...
متن کاملOptimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique
Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
دوره 12 3 شماره
صفحات -
تاریخ انتشار 2016