Double-arc volumetric modulated therapy improves dose distribution compared to static gantry IMRT and 3D conformal radiotherapy for adjuvant therapy of gastric cancer
نویسندگان
چکیده
BACKGROUND The objective of this study was to compare the dose distributions of RapidArc (RA), static gantry intensity-modulated radiotherapy (IMRT), and three-dimensional conformal radiotherapy (3DCRT) as adjuvant radiotherapy modalities for the treatment of gastric cancer. METHODS Fifteen patients with gastric cancer that underwent limited lymphadenectomy of perigastric lymph nodes were included in this study. Dosimetric values for a total dose of 45 Gy (1.8 Gy/day) were calculated for the RapidArc, IMRT, and 3DCRT modalities. The following parameters were compared: D99%, D1%, V95%, V107%, and conformity and homogeneity index values (CI and HI, respectively) for the planned target volume (PTV). Dose volume histogram (DVH) and dose distribution of the organs at risk (OAR), as the maximal dose to the spinal cord, V30 and V40 of the small bowel, and V20, V30 of liver and kidney were also assessed respectively. RESULTS RA, IMRT, and 3DCRT all achieved desirable PTV coverage. However, RA and IMRT significantly decreased D1% and V107%, and provided better CI and HI values compared with 3DCRT (P <0.05). Moreover, RA also achieved a significantly lower maximum dose for the spinal cord, liver V30, and kidney V20 compared to IMRT and 3DCRT; while the mean dose for these three organ types did not differ for the RA, IMRT, and 3DCRT plans. CONCLUSIONS Both RA and IMRT achieved favorable PTV coverage compared to 3DCRT. In addition, RA achieved better dosimetry than IMRT and 3DCRT, and provided better protection for the spinal cord, liver, and kidneys.
منابع مشابه
Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
متن کامل3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk
Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...
متن کاملTreatment planning for the lung cancer
Volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) are commonly used treatment techniques for cancer treatment, and both the VMAT and IMRT techniques use the photon beam (mega-voltage X-rays) to deliver radiation dose to the tumor. The capability of modulating radiation beam has increased the ability of delivering more conformal dose distributions to tumor ...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملPotential advantages of volumetric arc therapy in head and neck cancer.
BACKGROUND Intensity-modulated radiation therapy (IMRT) uses solid compensators or multileaf collimators to modulate the intensity of radiation in each field, delivering highly conformal dose distributions. This technique allows treating volumes with concave shapes when the target is close to a critical structure. The movement of multileaf collimator under computer control can modulate the dose...
متن کامل