Hydrophobicity parameters determined by reversed-phase liquid chromatography. XV: optimal conditions for prediction of log P(oct) by using RP-HPLC procedures.

نویسندگان

  • Chisako Yamagami
  • Kaname Kawase
  • Kyoko Iwaki
چکیده

The use of log k derived from reversed phase (RP)-HPLC retention times provides a convenient method for estimating log P(oct) values (P(oct): 1-octanol/water partition coefficient). In order to establish optimal HPLC conditions, the difference between chromatographic (C18 modified column and aqueous methanol eluents) and bulk solvent systems was examined by use of a batch-like equilibration with octane/aqueous methanol. Comparison of values for log P(O/M-W) (log P for the Octane/MeOH-Water partitioning system) and log k measured for monosubstituted pyrazines at different methanol concentrations, showed closest correlation (r, 0.94) with 50% aqueous methanol; and importantly, under these conditions, log k shows even better correlation (r, 0.99) with log P(oct). Effects of residual silanols on HPLC retention with C18 stationary phases were examined. The results show that, in the presence of a small quantity of accessible silanols, the use of 50% aqueous methanol (M50) as eluent yields values of log k directly proportional to log P(oct) in accord with our earlier proposal that use of log k(M50) provides a convenient means for rapid estimation and prediction of log P(oct).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lipophilicity measurement of drugs by reversed phase HPLC over Wide pH range using an alkaline-resistant silica-based stationary phase, XBridge Shield RP(18).

We propose a reversed phase HPLC (RP-HPLC) with an alkaline-resistant silica-based stationary phase, XBridge Shield RP(18), for the determination of the lipophilicity of drugs with diverse chemical nature ranging from acidic to basic. A set of 40 model compounds with well-defined solvatochromic parameters was selected to allow a broad distribution of structural properties. The chromatographic r...

متن کامل

EFFECTS OF TEMPERATURE AND PERCENTAGE OF ORGANIC MODIFIER ON RETENTION AND SELECTIVITY IN RP-HPLC USING SOLVATION PARAMETER MODEL

Effects of temperature and percentage of organic modifier were studied on retention and selectivity in RP-HPLC using solvation parameter model. The system constants were determined by multiple linear regression analysis from experimental values in the retention factor for a group of different solutes with known descriptors by computer using the program SPSS/PC. The experimental results showed t...

متن کامل

Reversed-phase Salt Assisted Liquid-liquid Extraction: A New Technique for Preconcentration and Determination of Crocin in Herbal Medicines by HPLC

A reversed-phase salt assisted liquid-liquid extraction (RP-SALLE) method was developed for the preconcentration and determination of trace crocin in herbal medicines by high-performance liquid chromatography (HPLC). In developed method, the roles of the aqueous and organic phases are inverted so that the analyte is extracted from the organic into the aqueous phase after salt addition and phase...

متن کامل

SEPARATION OF NONHISTONE HIGH MOBILITY GROUP (HMG) FROM HUMAN LYMPHOCYTES BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

The high mobility group (HMG) of nonhistone proteins have been investigated using two high performance liquid chromatographic techniques (HPLC). Reversed-phase HPLC under conditions of 50 mM triethylamine adjusted to pH 2.2 with phosphoric acid (solvent A) and 95% acetonitrile in water (solvent B) was used to separate proteins primarily on the basis of differences in the overall hydrophobi...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical & pharmaceutical bulletin

دوره 50 12  شماره 

صفحات  -

تاریخ انتشار 2002