In Vivo Accuracy of Two Electronic
نویسندگان
چکیده
locators (EFLs) based on different operation systems Root ZX and Propex II. Ten healthy adult patients needing premolar extractions due to orthodontic reasons participated in the study, providing a sample of 17 noncarious, non-restored, vital teeth (n= 24 canals). After coronal access preparation and cervical preflaring and prior to tooth extraction, the root canal length was measured alternating the two EFLs. All measurements were performed with K-files well fitted to the canal diameter at the level that each EFL indicated the apical foramen in their display (APEX or 0.0). The last K-file were fixed in place with cyanoacrylate, the tooth was extracted, and the apical 4 mm of each root were resected to measure the distance between the file tip and the apical foramen. The mean errors based on the absolute values of discrepancies were 0.30 ± 0.29 mm (Root ZX) and 0.32 ± 0.27 mm (Propex II). Analysis by the Wilcoxon test for paired samples showed no statistically significant differences between the electronic canal measurements performed with the EFLs (p=0.587). The apical foramen was accurately located in 75% (Root ZX) and 66.7% (Propex II) of the cases, considering a ±0.5 mm error margin, with no statistically significant difference by the chi-square test. Despite having different measurement mechanisms, both EFLs were capable of locating the apical foramen with high accuracy in vivo. Under the tested clinical conditions, Root ZX and Propex II displayed similar results. In Vivo Accuracy of Two Electronic F o r amen Lo c a t o r s Ba s ed on D i f f e ren t Opera t ion Sys tems
منابع مشابه
ارزیابی دقت دو دستگاه آپکس یاب الکترونیکی (Electronic Apex Locator) از نسل چهارم در تعیین طول کانال (In-vivo)
Background and Aim: Determining correct working length in root canal therapy is of great importance in successful treatment. The purpose of this study was to compare the accuracy of two electronic apex locators of fourth generation, Raypex4 and Apit7, in determining working length in vivo. Materials and Methods: In this test evaluation study performed at Dental School of Tehran University, a to...
متن کاملEvaluation of the accuracy of two apex locators in endodontic treatment and retreatments: an ex vivo study
Introduction: Working length determination is important in successful endodontic treatment and retreatment.This study evaluated the accuracy of two electronic apex locators Root ZX and Raypex®6 (EALs) in determining the electronic working length (EWL) of the root canals in endodontic treatment and retreatment. Materials and Methods: Access cavities were prepared on forty extracted, singl...
متن کاملارزیابی دقت یک نوع Electronic Apex Locator در تعیین طول کانال دندانهای شیری در شرایط In vivo
Background and Aim: Radiography is the most commonly used technique in root canal length determination, but its application in pedodontics is difficult due to many problems such as radiation hazards, superimposition of permanent teeth buds and uncooperative children. The aim of this study was to investigate the accuracy of an electronic apex locator (Dentaport ZX) in measuring the root canal le...
متن کاملIn vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination
In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...
متن کاملThe effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants
BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants. METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of the canals was preflared, and the length to the major foramen was ...
متن کاملPretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)
Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...
متن کامل