INTRODUCTION: Non-resonance method (NORM) for MR signal excitation and reception has been advocated due to its unmatched advantages in multinuclear and parallel imaging applications (1). In this work, we established a simulation model and systematically investigated the reception efficiency and SNR of the NORM technology using numerical analysis and in vivo MR imaging. The results were validated with the conventional resonant coil method. For comparison, human leg images at 7T were acquired and presented. METHOD: Although the non-resonance circuitry can be realized in different ways, in this study, we used microstrip to implement the non-resonance method. The connection setup for non-resonance method in MR experiment is shown in Fig 1. To evaluate the reception efficiency using numerical method, a model for non-resonant and resonant coils was established as shown in Fig 2. The radiation source was used to mimic excited bulk spin.
منابع مشابه
Advanced MR Imaging Technologies in Fetuses.
Fetal Magnetic Resonance Imaging (MRI) on clinical scanners has increasingly been realized as a powerful imaging tool and applied for studying the brain abnormalities and the potential of neurodevelopmental disabilities in vivo. The primarily used multi-echo fast imaging sequences reduce the motion artifacts with a tradeoff of image Signal-to-Noise Ratio (SNR) and resolution. In Radio Frequency...
متن کاملNon-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...
متن کاملCompensation of MRI T1-weighted spin-echo images for radio-frequency inhomogeneities
We propose a correction method for magnetic resonance (MR) images to eliminate the effects of the inhomogeneity of the radio-frequency (RF) pulses and of the sensivity of the RF reception particularly in the case of T1-weighted images. In this case the effects of the pulse inhomogeneities vary with the tissues, which prevents the use of simpler correction techniques based on a global multiplica...
متن کاملThe design of dedicated RF coils for mouse MR
Introduction MR imaging of mice in medical research has allowed for well controlled disease models for pharmokinetic and dynamic tests of new contrast and therapeutic agents. However, the volume of interest in mice is typically several orders of magnitude smaller than in humans, and concomitantly the number of spins that contribute to the signal in an MR exam will be substantially smaller, ther...
متن کاملImplications of HTS Film Linearity on RF Coil Design and Assessment at 9.4 T
INTRODUCTION High-temperature superconducting (HTS) Helmholtz coil pairs have been shown to provide substantial increases in signal-to-noise ratio (SNR) for applications in NMR and MR microscopy (1, 2). One limitation of HTS coils is that their non-linear response to applied power produces distortion of shaped RF pulses (3). Through the use of a previously reported field mapping technique (4) m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008