Silicon avalanche photodiodes operated above breakdown, in Geiger mode, can be sensitive enough to allow single photon detection. An inherent limit to GMAPD sensitivity is the noise caused by thermally generated carriers. This noise manifests itself as extraneous counts in the absence of light and is termed the dark count. The presence of the dark count in GM-APD detectors reduces the signal to noise ratio and increases the integration times that are necessary for photon detection. A 1-Dimensional model of the dark count in GM-APD detectors was developed and dark count was found to depend predominantly on carrier generation through Shockley-Read-Hall (SRH) generation centres and secondly on thermal diffusion of minority carriers in the bulk. Simulations performed show that minimisation of the dark count is limited by bulk diffusion of minority carriers. The reduction of process induced damage minimises the dark count and allows theoretically minimum dark counts to be achieved.
منابع مشابه
Study of radiation damage induced by 82MeV protons on multi-pixel Geiger-mode avalanche photodiodes
Results from a study on the radiation hardness of multi-pixel Geiger-mode avalanche photodiodes (G-APDs) are presented. Recently developed G-APDs from five manufacturers (Hamamatsu (Japan), CPTA/Photonique (Russia/Switzerland), Zecotek (Singapore), Pulsar (Russia) and FBK-IRST (Italy)) were exposed to 82MeV protons at fluences up to 10 protons/cm at the Paul Scherrer Institute. The G-APD’s main...
متن کاملCharacterisation of Geiger-mode avalanche photodiodes for medical imaging applications
Recently developed multipixel Geiger-mode avalanche photodiodes (G-APDs) are very promising candidates for the detection of light in medical imaging instruments (e.g. positron emission tomography) as well as in high-energy physics experiments and astrophysical applications. G-APDs are especially well suited for morpho-functional imaging (multimodality PET/CT, SPECT/CT, PET/MRI, SPECT/MRI). G-AP...
متن کاملIII-Nitride Based Avalanche Photo Detectors
Research into III-Nitride based avalanche photodiodes (APDs) is motivated by the need for high sensitivity ultraviolet (UV) detectors in numerous civilian and military applications. By designing III-Nitride photodetectors that utilize low-noise impact ionization high internal gain can be realized—GaN APDs operating in Geiger mode can achieve gains exceeding 1×10. Thus with careful design, it be...
متن کاملSignal-to-noise ratio of Geiger-mode avalanche photodiode single-photon counting detectors
Geiger-mode avalanche photodiodes (GM-APDs) use the avalanche mechanism of semiconductors to amplify signals in individual pixels. With proper thresholding, a pixel will be either “on” (avalanching) or “off.” This discrete detection scheme eliminates read noise, which makes these devices capable of counting single photons. Using these detectors for imaging applications requires a well-developed...
متن کاملHigh performance InP Geiger-mode SWIR avalanche photodiodes
LAser Detection And Ranging (LADAR) is a promising tool for precise 3D-imaging, which enables field surveillance and target identification under low-light-level conditions in many military applications. For the time resolution and sensitivity requirements of LADAR applications, InGaAsP/InP Geiger-mode (GM) avalanche photodiodes (APDs) excel in the spectrum band between 1.0~1.6 μm. Previously MI...