Hemoglobin interference from in vivo hemolysis.
نویسندگان
چکیده
Laboratory values for specimens from a case of intravascular hemolysis showed that hemoglobin was significantly increased and thus could interfere with the determination of other analytes. We studied this problem by adding increasing amounts of purified hemoglobin (to a maximum concentration of 19.3 mg/L) to aliquots of pooled serum samples. The hemoglobin significantly interfered with the determination of only five analytes: albumin, aspartate aminotransferase, direct bilirubin, and total protein on the SMAC, and creatinine on the Astra. We propose that for cases of proven intravascular hemolysis, values for only the analytes not affected by hemoglobin should be reported. We find lactate dehydrogenase activity useful in assessing the components of in vivo hemolysis; the differences between serum and plasma values for potassium, lactate dehydrogenase, and hemoglobin are related to in vitro hemolysis. Criteria for specimen collection and assessment of type of hemolysis are proposed.
منابع مشابه
Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays.
The effect of hemolysis on several assays performed with the Hitachi 717 was quantified by relating the amount of error to the concentration of hemoglobin. Hemolysis interference was judged clinically significant when analyte concentration varied by > 10% from the initial value. Hemolysis interference was significant for alkaline phosphatase, aspartate aminotransferase, alpha-amylase, bilirubin...
متن کاملMechanism of interference of a polymerized hemoglobin blood substitute in an alkaline phosphatase method.
BACKGROUND Hemoglobin-based oxygen carriers can cause profound interferences in many analytical procedures. We determined the mechanism of interference in the assay of alkaline phosphatase activity and identified approaches that might be used to correct for this interference. METHODS Interference of a polymerized hemoglobin blood substitute with the assay of alkaline phosphatase was examined ...
متن کاملMechanism of interference by hemolysis in immunoassays and requirements for sample quality.
To the Editor: Cardiac troponin I (cTnI) is considered organ-specific, and few circumstances other than heart muscle injury produce false increases in plasma. We encountered unexpectedly high cTnI in a two-site, enzyme-linked immunoassay using poly-clonal goat antibody (1) when by mistake, two visually clear but grossly hemolyzed samples from one patient were not rejected by the laboratory. Hem...
متن کاملEvaluation of hemoglobin interference in capillary heel-stick samples collected for determination of neonatal bilirubin.
OBJECTIVE In this study, we determined the assay performance criteria necessary to produce acceptable results for >or=98% of neonate bilirubin samples collected by capillary heel-stick. STUDY DESIGN AND METHODS We determined serum free hemoglobin levels in 151 heel-stick serum samples to determine the hemolysis level. We then tested the effect of hemolysis on total bilirubin levels determined...
متن کاملInterpretation of hemolysis tests following administration of a second-generation hemoglobin-based oxygen carrier.
Hemoglobin released into the circulation during hemolysis or therapy with chemically modified hemoglobins, exert oxidative and NO-scavenging toxic effects. Pyridoxalated hemoglobin polyoxyethylene conjugate (PHP) is one of the second-generation hemoglobin-based oxygen carriers (HBOCs). We wanted to investigate the metabolism of PHP with a special focus on its consequences for interpreting hemol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 31 9 شماره
صفحات -
تاریخ انتشار 1985