Real-time cardiac phase contrast MRI blood flow including Valsalva and Mueller maneuver. Initial experiences

نویسندگان

  • Jan M Sohns
  • Christina Unterberg-Buchwald
  • Johannes T Kowallick
  • Michael Steinmetz
  • Christina Schulte
  • Wieland Staab
  • Arun Joseph
  • Klaus-Dietmar Merboldt
  • Dirk Voit
  • Shuo Zhang
  • Martin Uecker
  • Jens Frahm
  • Joachim Lotz
چکیده

Background A high resolution real-time phase-contrast MRI flow technique was used to measure flow dynamics in the ascending aorta as well as superior vena cava. MRI technique based on undersampled radial fast low-angle shot acquisitions with phase-sensitive image reconstructions by regularized nonlinear inversion. Normal flow values as well as flow measurements during physiologic stress tests like Valsalva (increased intrathoracic pressure) and Mueller (decreased intrathoracic pressure, reverse of Valsalva maneuver) were obtained in healthy volunteers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time blood flow imaging using autocalibrated spiral sensitivity encoding.

A novel spiral phase contrast (PC) technique was developed for high temporal resolution imaging of blood flow without cardiac gating. An autocalibrated spiral sensitivity encoding (SENSE) method is introduced and used to reconstruct PC images. Numerical simulations and a flow phantom study were performed to validate the technique. To study the accuracy of the flow measurement in vivo, a high-re...

متن کامل

Physiology-based MR imaging assessment of CSF flow at the foramen magnum with a valsalva maneuver.

BACKGROUND AND PURPOSE MR imaging is currently not used to evaluate CSF flow changes due to short-lasting physiological maneuvers. The purpose of this study was to evaluate the ability of MR imaging to assess the CSF flow response to a Valsalva maneuver in healthy participants. MATERIALS AND METHODS A cardiac-gated fast cine-PC sequence with ≤15-second acquisition time was used to assess CSF ...

متن کامل

Comparison of agitated saline mixed with blood to agitated saline alone in detecting right-to-left shunt during contrast- transcranial Doppler sonography examination.

PURPOSE To evaluate a technique for contrast agent preparation as mixing the patients' blood with agitated saline and to compare it with agitated saline alone in diagnosis of cardiac right-to-left shunt in regard to their sensitivity, time window, and distribution of artificially induced microembolic signals. METHODS Fifty-two patients with stroke who had Transesophageal echocardiography prov...

متن کامل

Influence of the Valsalva maneuver on cardiac hemodynamics and right to left shunt in patients with patent foramen ovale

The purpose of this study was to investigate the influence of the Valsalva maneuver (VM) on cardiac hemodynamics in patients with patent foramen ovale (PFO). Sixty-five patients who were highly suspected to have PFO were included. The changes in E, A, E/A ratio of mitral valve blood flow, E, A, E/A ratio of tricuspid valve blood flow, left ventricular end-diastolic volume, area and right atrial...

متن کامل

Effect of Breath Holding on Blood Flow Measurement using Fast Velocity Encoded Cine MR Imaging

Introduction Velocity encoded tine (VEC) MR imaging provides quantitative assessment of blood flow in the cardiovascular system. With use of segmented k-space fast VEC MR imaging, noninvasive assessment of blood flow and vasodilator flow reserve in the coronary artery and coronary arterial bypass graft can be obtained within a single breath-hold time. However, it has been pointed out that blood...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013