Cardiopulmonary resuscitation manikins are used for training personnel in performing cardiopulmonary resuscitation. State-of-the-art cardiopulmonary resuscitation manikins are still anatomically and physiologically low-fidelity designs. The aim of this research was to design a manikin that offers high anatomical and physiological fidelity and has a cardiac and respiratory system along with integrated flow sensors to monitor cardiac output and air displacement in response to cardiopulmonary resuscitation. This manikin was designed in accordance with anatomical dimensions using a polyoxymethylene rib cage connected to a vertebral column from an anatomical female model. The respiratory system was composed of silicon-coated memory foam mimicking lungs, a polyvinylchloride bronchus and a latex trachea. The cardiovascular system was composed of two sets of latex tubing representing the pulmonary and aortic arteries which were connected to latex balloons mimicking the ventricles and lumped abdominal volumes, respectively. These balloons were filled with Life/form simulation blood and placed inside polyether foam. The respiratory and cardiovascular systems were equipped with flow sensors to gather data in response to chest compressions. Three non-medical professionals performed chest compressions on this manikin yielding data corresponding to force-displacement while the flow sensors provided feedback. The force-displacement tests on this manikin show a desirable nonlinear behaviour mimicking chest compressions during cardiopulmonary resuscitation in humans. In addition, the flow sensors provide valuable data on the internal effects of cardiopulmonary resuscitation. In conclusion, scientifically designed and anatomically high-fidelity designs of cardiopulmonary resuscitation manikins that embed flow sensors can improve physiological fidelity and provide useful feedback data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Layperson training for cardiopulmonary resuscitation: when less is better.

PURPOSE OF REVIEW Basic cardiopulmonary resuscitation, including use of automated external defibrillators, unequivocally saves lives. However, even when motivated, those wishing to acquire training traditionally have faced a myriad of barriers including the typical time commitment (3-4 h) and the number of certified instructors and equipment caches required. RECENT FINDINGS The recent introdu...

متن کامل

Efficacy of acute care health care providers in cardiopulmonary resuscitation compressions in normal and obese adult simulation manikins.

Annually, over 350,000 persons require cardiopulmonary resuscitation (CPR), either in or outside of the hospital. With obesity a rising health issue in the United States, concerns exist regarding the efficacy of quality compressions for CPR in obese patients. The aims of this study were to determine if the compressions for three adult simulation manikins (normal, obese, and morbidly obese) met ...

متن کامل

The Effect of Computer Simulation and Mannequin on Nursing Students’ Perception of Self-efficacy in Cardiopulmonary Resuscitation

Introduction: Resuscitation self-efficacy is defined as a judgment of perceived capability to organize and execute the process of care during cardiopulmonary resuscitation. It is believed to be an important factor in teaching vital nursing skills especially cardiopulmonary resuscitation. Therefore, this study aimed to investigate the impact of mannequin-based simulation and computer-based simul...

متن کامل

Numerical Modeling of an Innovative Bipolar Plate Design Based on the Leaf Venation Patterns for PEM Fuel Cells

Flow channel design on bipolar plates has a direct effect on Proton Exchange Membrane (PEM) fuel cell performance. It has been found out that the flow field design has a deterministic role on the mass transport and water management, and therefore on the achieved power in PEM Fuel cells. This study concentrates on improvements in the fuel cell performance through optimization of channel dimensio...

متن کامل

Rib cage recreation: Towards realistic neonatal manikin construction using MRI scanning and 3D printing

Within our research, the human body plays a central role. The human body is one of the most visually fascinating shapes, but our research goes further. We focus on the dynamic aspects of the body regarding interaction. Within this paper, we focus on the creation of manikins for the training of chest compressions, which is an essential procedure during cardiopulmonary resuscitation (CPR). We exp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 231  شماره 

صفحات  -

تاریخ انتشار 2017