MRI active guidewire with an embedded temperature probe and providing a distinct tip signal to enhance clinical safety
نویسندگان
چکیده
BACKGROUND The field of interventional cardiovascular MRI is hampered by the unavailability of active guidewires that are both safe and conspicuous. Heating of conductive guidewires is difficult to predict in vivo and disruptive to measure using external probes. We describe a clinical-grade 0.035" (0.89 mm) guidewire for MRI right and left heart catheterization at 1.5 T that has an internal probe to monitor temperature in real-time, and that has both tip and shaft visibility as well as suitable flexibility. METHODS The design has an internal fiberoptic temperature probe, as well as a distal solenoid to enhance tip visibility on a loopless antenna. We tested different tip-solenoid configurations to balance heating and signal profiles. We tested mechanical performance in vitro and in vivo in comparison with a popular clinical nitinol guidewire. RESULTS The solenoid displaced the point of maximal heating ("hot spot") from the tip to a more proximal location where it can be measured without impairing guidewire flexion. Probe pullback allowed creation of lengthwise guidewire temperature maps that allowed rapid evaluation of design prototypes. Distal-only solenoid attachment offered the best compromise between tip visibility and heating among design candidates. When fixed at the hot spot, the internal probe consistently reflected the maximum temperature compared external probes.Real-time temperature monitoring was performed during porcine left heart catheterization. Heating was negligible using normal operating parameters (flip angle, 45°; SAR, 1.01 W/kg); the temperature increased by 4.2°C only during high RF power mode (flip angle, 90°; SAR, 3.96 W/kg) and only when the guidewire was isolated from blood cooling effects by an introducer sheath. The tip flexibility and in vivo performance of the final guidewire design were similar to a popular commercial guidewire. CONCLUSIONS We integrated a fiberoptic temperature probe inside a 0.035" MRI guidewire. Real-time monitoring helps detect deleterious heating during use, without impairing mechanical guidewire operation, and without impairing MRI visibility. We therefore need not rely on prediction to ensure safe clinical operation. Future implementations may modulate specific absorption rate (SAR) based on temperature feedback.
منابع مشابه
Two channel passive visualization of a nitinol guidewire with iron markers
Background MRI-guidance for cardiovascular catheterization is appealing to reduce ionizing radiation exposure and to enable novel procedures. “Active” guidewire-antennas for MRI-guided procedures are often designed such that the tip and shaft have distinct signals [1] to improve navigation and to make it obvious when the tip moves out of plane. Here we present a method to isolate the signal fro...
متن کاملAn Active Two Channel Guidewire for Interventional Cardiovascular Mri
INTRODUCTION The success and safety of interventional magnetic resonance imaging (iMRI) procedures require conspicuous intravascular instruments that can be distinguished from surrounding tissues. iMRI guidewires must navigate diseased tortuous structures without damaging them and while retaining mechanical integrity. The device tip is most likely to injure, disrupt, or perforate diseased tissu...
متن کاملA novel active MR probe using a miniaturized optical link for a 1.5-T MRI scanner.
Applying an active intravascular MR catheter device that allows signal transmission from the catheter tip requires special means to avoid radiofrequency-induced heating. This article presents a novel, miniaturized all-optical active MR probe to use with real-time MRI in minimally invasive interventions for catheter guidance and intravascular imaging. An optical link transmits the received MR si...
متن کاملAssessment of aquatic environmental quality using gyrodactylus sp. as a living probe: parasitic biomonitoring of ecosystem health
Biological indicators are species that can be employed to monitor environmental quality and ecosystem health. Different groups of organisms such as plants, animals, bacteria and parasites regularly produce certain molecular signal in response to changes in their environmental milieu. Parasites are important tools for providing wealth of information on physicochemical quality, environmental stre...
متن کاملSPIO-Annexin V, a potential probe for MRI detection of radiation induced apoptosis
Background: Finding a suitable method for rapid, accurate and reliable estimation of absorbed dose has high priority in management of the radiation exposed persons. Shortly after radiation exposure, apoptosis is a major detriment in proliferative tissues such as the hematopoietic system. Therefore, quantification of apoptosis in these tissues could be useful for rapid estimation of radiation ex...
متن کامل