Evaluation of the right atrial venous oxygen saturation as a physiologic monitor in a neonatal model.

نویسندگان

  • R B Hirschl
  • P Palmer
  • K F Heiss
  • K Hultquist
  • F Fazzalari
  • R H Bartlett
چکیده

Pulmonary artery (PA) mixed venous saturation (SvO2) has become a crucial monitor in the adult intensive care unit, but is not used in neonates because of the difficulty in PA catheterization. We evaluated the possibility of utilizing the right atrial venous oxygen saturation (RAvO2), which is easily accessed in the neonate, as a monitor of the effects of mechanical ventilation and intravascular volume in an animal model selected to be the size of the human neonate. A continuous RAvO2 monitoring catheter was placed into the right atrium of 16 normal rabbits (2.2 to 4.1 kg). Oxygen delivery was manipulated by alterations in peak inspiratory pressure (PIP) (n = 6), positive end-expiratory pressure (PEEP) (n = 6), or by progressive hypovolemia (n = 4). RAvO2 decreased with onset of mechanical ventilation alone from 69% +/- 6% to 61% +/- 5% (P < .01). As the PIP was increased from 12 to 21 cm H2O, the RAvO2 progressively decreased from 59% +/- 4% to 49% +/- 6% (P < .05). As the PEEP was increased from 3 to 9 cm H2O, the RAvO2 progressively decreased from 64% +/- 5% to 33% +/- 16% (P < .01). RAvO2 approached baseline after return to continuous positive airway pressure (CPAP) of 3 cm H2O. Progressive phlebotomy to a total of 10 mL/kg resulted in a decrease in RAvO2 from 70% +/- 6% to 27% +/- 5% (P < .001). Volume resuscitation resulted in an increase in RAvO2 to near baseline. Peripheral arterial oxygen saturation remained at a constant 100% throughout each protocol.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Severe Persistant Cyanosis in a Newborn Due to Prominent Eustachian Valve

ABSTRACTThe valves of right horn of systemic venous sinus are prominent structures within the right atrium during early embryonic period. Involution of these structures may not be complete, resulting in a spectrum of anatomical presentations such as cyanosis. A full-term male neonate referred to our hospital for precise evaluation of severe cyanosis on the first day of life. Echocardiographic e...

متن کامل

Usefulness of central venous oxygen saturation monitoring during bidirectional Glenn shunt.

A PediaSat™ oximetry catheter (PediaSat: Edwards Lifesciences Co., Ltd., Irvine, CA, U. S. A.), which facilitates continuous measurement of central venous oxygen saturation (ScvO2), may be useful for surgery for pediatric congenital heart disease. We used PediaSat during a bidirectional Glenn shunt. The patient was a 13-month-old boy. Under a diagnosis of left single ventricle (pulmonary atresi...

متن کامل

Effect of Blood Sampling Site on the Changes in the Physiological Indices of Preterm Infants: A Crossover Clinical Trial

Background: Venipuncture is one of the most painful and common interventions in Neonatal ward. A preterm infant can not cope long-lasting physiologic stresses; therefore, the pain caused by blood sampling may change the infant’s physiologic responses to the stress. This present study aim is to investigated and compare physiologic changes (pulse rate and oxygen saturation) in two sites of blood ...

متن کامل

Effect of Different Positions on Arterial Oxygen Saturation during Enteral Feeding of Preterm Infants Admitted to Neonatal Intensive Care Units

Background: This study aimed to determine the effects of various positions on the arterial oxygen saturation during enteral feeding of preterm infants admitted to Neonatal Intensive Care Units (NICUs). It is assumed that different body positions influence arterial oxygen saturation during enteral feeding.Methods: This crossover clinical trial included 88 infants. The inclusion criteria we...

متن کامل

Near-infrared spectroscopy to monitor cerebral oxygen saturation in single-ventricle physiology.

OBJECTIVES Near-infrared spectroscopy monitors cerebral oxygen saturation. This parameter parallels jugular venous oxygen saturation and reflects the balance between cerebral oxygen supply and demand. Experience with near-infrared spectroscopy in univentricular physiology is limited. This study explores the relationship between cerebral oxygen saturation, jugular venous oxygen saturation, and o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pediatric surgery

دوره 28 7  شماره 

صفحات  -

تاریخ انتشار 1993