Calibration of Contactless Pulse Oximetry

نویسندگان

  • Wim Verkruysse
  • Marek Bartula
  • Erik Bresch
  • Mukul Rocque
  • Mohammed Meftah
  • Ihor Kirenko
چکیده

BACKGROUND Contactless, camera-based photoplethysmography (PPG) interrogates shallower skin layers than conventional contact probes, either transmissive or reflective. This raises questions on the calibratability of camera-based pulse oximetry. METHODS We made video recordings of the foreheads of 41 healthy adults at 660 and 840 nm, and remote PPG signals were extracted. Subjects were in normoxic, hypoxic, and low temperature conditions. Ratio-of-ratios were compared to reference SpO2 from 4 contact probes. RESULTS A calibration curve based on artifact-free data was determined for a population of 26 individuals. For an SpO2 range of approximately 83% to 100% and discarding short-term errors, a root mean square error of 1.15% was found with an upper 99% one-sided confidence limit of 1.65%. Under normoxic conditions, a decrease in ambient temperature from 23 to 7°C resulted in a calibration error of 0.1% (±1.3%, 99% confidence interval) based on measurements for 3 subjects. PPG signal strengths varied strongly among individuals from about 0.9 × 10 to 4.6 × 10 for the infrared wavelength. CONCLUSIONS For healthy adults, the results present strong evidence that camera-based contactless pulse oximetry is fundamentally feasible because long-term (eg, 10 minutes) error stemming from variation among individuals expressed as A*rms is significantly lower (<1.65%) than that required by the International Organization for Standardization standard (<4%) with the notion that short-term errors should be added. A first illustration of such errors has been provided with A**rms = 2.54% for 40 individuals, including 6 with dark skin. Low signal strength and subject motion present critical challenges that will have to be addressed to make camera-based pulse oximetry practically feasible.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals

Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...

متن کامل

Calibration-Free Pulse Oximetry Based on Two Wavelengths in the Infrared — A Preliminary Study

The assessment of oxygen saturation in arterial blood by pulse oximetry (SpO₂) is based on the different light absorption spectra for oxygenated and deoxygenated hemoglobin and the analysis of photoplethysmographic (PPG) signals acquired at two wavelengths. Commercial pulse oximeters use two wavelengths in the red and infrared regions which have different pathlengths and the relationship betwee...

متن کامل

Evaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals

Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...

متن کامل

Evaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns

Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...

متن کامل

Pulse oximetry: theory and applications for noninvasive monitoring.

Noninvasive measurement of arterial oxygen saturation (SaO2) by pulse oximetry is widely acknowledged to be one of the most important technological advances in monitoring clinical patients. Pulse oximeters compute SaO2 by measuring differences in the visible and near infrared absorbances of fully oxygenated and deoxygenated arterial blood. Unlike clinical blood gas analyzers, which require a sa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 124  شماره 

صفحات  -

تاریخ انتشار 2017