Comparison of 1.5T and 3T 1H MR Spectroscopy for Human Brain Tumors

نویسندگان

  • Ji-hoon Kim
  • Kee-Hyun Chang
  • Dong Gyu Na
  • In Chan Song
  • Seung Ja Kim
  • Bae Ju Kwon
  • Moon Hee Han
چکیده

OBJECTIVE We wanted to estimate the practical improvements of 3T proton MR spectroscopy ((1)H MRS) as compared with 1.5T (1)H MRS for the evaluation of human brain tumors. MATERIALS AND METHODS Single voxel (1)H MRS was performed at both 1.5T and 3T in 13 patients suffering with brain tumors. Using the same data acquisition parameters at both field strengths, the (1)H MRS spectra were obtained with a short echo time (TE) (35 msec) and an intermediate TE (144 msec) with the voxel size ranging from 2.0 cm(3) to 8.7 cm(3). The signal to noise ratios (SNRs) of the metabolites (myoinositol [MI], choline compounds [Cho], creatine /phosphocreatine [Cr], N-acetyl-aspartate [NAA], lipid and lactate [LL]) and the metabolite ratios of MI/Cr, Cho/Cr, Cho/NAA and LL/Cr were compared at both TEs between the two field strengths in each brain tumor. The degrees of spectral resolution between the Cho and Cr peaks were qualitatively compared between the two field strengths in each brain tumor. RESULTS The SNRs of the metabolites at 3T demonstrated 49-73% increase at a short TE (p < 0.01) and only 2-12% increase at an intermediate TE (p > 0.05) compared with those of 1.5T. The SNR of inverted lactate at an intermediate TE decreased down to 49% with poorer inversion at 3T (p < 0.05). There was no significant difference in the metabolite ratios between the two field strengths. The degrees of the spectral resolution at 3T were slightly superior to those of 1.5T at a short TE. CONCLUSION As compared with 1.5T, 3T 1H MRS demonstrated 49-73% SNR increase in the cerebral metabolites and slightly superior spectral resolution only at a short TE, but little at an intermediate TE, in the brain tumors. There was no significant difference in the metabolite ratios between the two field strengths.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of pattern recognition techniques for classification of pediatric brain tumors by in vivo 3T 1H‐MR spectroscopy—A multi‐center study

PURPOSE 3T magnetic resonance scanners have boosted clinical application of 1 H-MR spectroscopy (MRS) by offering an improved signal-to-noise ratio and increased spectral resolution, thereby identifying more metabolites and extending the range of metabolic information. Spectroscopic data from clinical 1.5T MR scanners has been shown to discriminate between pediatric brain tumors by applying mac...

متن کامل

Spinal Cord Diffusion Tensor Imaging (DTI) and 1H-MR Spectroscopy (MRS) at 1.5T and 3T

Introduction MRI is an important modality in the assessment of spinal cord (SC) diseases. Conventional examinations are based on anatomic T1 and T2-weighted images but new techniques such as Diffusion Tensor Imaging (DTI) and single-voxel 1H-MR spectroscopy (SV-MRS) tend to be used in order to better described the pathology and understand the underlying mechanisms. Several difficulties, includi...

متن کامل

Field, coil, and echo-time influence on sensitivity and reproducibility of brain proton MR spectroscopy.

BACKGROUND AND PURPOSE Clinical MR imaging scanners now offer many choices of hardware configurations that were not available in the first 25 years of their existence. Our goal was to assess the influence of coil technology, magnetic field strength, and echo time (TE) on the sensitivity, reflected by the signal intensity-to-noise-ratio (SNR) and reproducibility of proton MR spectroscopy (1H-MR ...

متن کامل

3T MR imaging of contrast enhancing brain tumors. Intra-individual comparison of standard and half-standard clinical dose at 3T and 1.5T

C. Krautmacher, H. Tschampa, F. Träber, W. A. Willinek, M. Born, J. Textor, H. Urbach, C. Kuhl, J. Gieseke, H. H. Schild Department of Radiology, University of Bonn, Germany, Philips Medical Systems, Germany Introduction Gadolinium-contrast enhanced MR imaging is a gold standard in the diagnosis of brain tumors. In clinical practice, i.e. working with field strengths of up to 1.5T, 0.1mmol/kg b...

متن کامل

Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study

OBJECTIVE Cochlear implants (CIs) are standard treatment for postlingually deafened individuals and prelingually deafened children. This human cadaver study evaluated diagnostic usefulness, image quality and artifacts in 1.5T and 3T magnetic resonance (MR) brain scans after CI with a removable magnet. METHODS Three criteria (diagnostic usefulness, image quality, artifacts) were assessed at 1....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2006