Do atrial tachyarrhythmias beget ventricular tachyarrhythmias in defibrillator recipients?

نویسندگان

  • Kenneth M Stein
  • David E Euler
  • Rahul Mehra
  • Karlheinz Seidl
  • David J Slotwiner
  • Suneet Mittal
  • Steven M Markowitz
  • Bruce B Lerman
چکیده

OBJECTIVES This study was designed to analyze the incidence of "dual tachycardia"-ventricular tachycardia (VT) or ventricular fibrillation (VF) preceded by paroxysmal atrial tachycardia (AT) or atrial fibrillation (AF)-in patients receiving dual-chamber implantable cardioverter defibrillators (ICDs). BACKGROUND Paroxysmal AT/AF occurs commonly in patients who receive ICDs for the treatment of life-threatening VT/VF. Although AF is associated with an adverse prognosis in the setting of structural heart disease, the relationship between AT/AF and VT/VF is unclear. METHODS We followed 537 patients undergoing implantation of the Jewel AF ICD (Model 7250, Medtronic, Minneapolis, Minnesota) for 11.4 +/- 8.2 months. These included 398 patients with a history of at least two episodes of AT or AF during the preceding year as well as 139 patients enrolled because of VT/VF alone. RESULTS There were 233 dual tachycardia episodes in 45 patients during follow-up. Overall, 8.9% of episodes detected as VT/VF were dual tachycardias, and 20.3% of patients with VT/VF had at least one dual tachycardia episode. The median duration of AT/AF preceding the first VT/VF detection was 1.09 h (25% to 75% quartile 0.24 to 33.4 h). When AT/AF continued between two consecutive VT/VF detections, the median interdetection interval was 11 min. When AT/AF terminated either because of a ventricular therapy or spontaneously, the median interdetection interval was prolonged to 71 h (p < 0.001). CONCLUSIONS Dual tachycardia is common in ICD recipients with a history of AT/AF. The duration of AT/AF preceding the first VT/VF detection is < or =1 h about 50% of the time. Termination of the AT/AF significantly delays the time to the next VT/VF detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of a dual chamber defibrillator with atrial antitachycardia functions in treating spontaneous atrial tachyarrhythmias in patients with life-threatening ventricular tachyarrhythmias.

BACKGROUND Atrial fibrillation has a high incidence in patients wearing an implantable cardioverter defibrillator for ventricular tachyarrhythmias and may lead to palpitations, heart failure, angina, stroke and inappropriate defibrillator discharge. The aim of the study was to evaluate the efficacy of a dual chamber defibrillator with atrial antitachycardia functions in treating spontaneous atr...

متن کامل

Efficacy of pacing therapies for treating atrial tachyarrhythmias in patients with ventricular arrhythmias receiving a dual-chamber implantable cardioverter defibrillator.

BACKGROUND Although overdrive pacing for treating atrial flutter is well established, the efficacy of device-based atrial pacing for treating spontaneous atrial tachyarrhythmias in patients with implantable cardioverter defibrillators (ICD) is unknown. This study evaluated the efficacy of novel pacing therapies for treating atrial tachyarrhythmias in patients receiving a dual-chamber ICD to tre...

متن کامل

Atrial therapies reduce atrial arrhythmia burden in defibrillator patients.

BACKGROUND Approximately 25% of patients who receive an implantable cardioverter-defibrillator (ICD) to treat ventricular tachyarrhythmias have documented atrial tachyarrhythmias before implantation. This study assessed the ability of device-based prevention and termination therapies to reduce the burden of spontaneous atrial tachyarrhythmias. METHODS AND RESULTS Patients with a standard indi...

متن کامل

Trouble Shooting of ICD Therapy: Inappropriate Shock

Patients with an implantable cardioverter defibrillator (ICD) can undergo inappropriate therapies (shock or antitachycardia pacing) if electrical activity not originating in the ventricle is wrongly recognized as ventricular by the device. Inappropriate therapy leading to shocks is not innocuous; consequences include pain and its psychological sequelae, particularly anxiety, as well as inductio...

متن کامل

Prevention of inappropriate therapy in implantable cardioverter-defibrillators: results of a prospective, randomized study of tachyarrhythmia detection algorithms.

OBJECTIVES The purpose of this randomized study was to investigate the performance of single- and dual-chamber tachyarrhythmia detection algorithms. BACKGROUND A proposed benefit of dual-chamber implantable cardioverter-defibrillators (ICDs) is improved specificity of tachyarrhythmia detection. METHODS All ICD candidates received a dual-chamber ICD and were randomized to programmed single- ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 2002