Farrington, T and Coward, T and Onambele-Pearson, G and Taylor, RL and Earl, P and Winwood, K (2015)The effect of model inclination during fabri- cation on mouthguard calliper-measured and CT scan-assessed thickness

ثبت نشده
چکیده

Aim: Excessive material thinning has been observed in the production of custom-made mouthguards in a number of studies, due to production anomalies that may lead to such thinning. This study investigated the effect of thinning material patterns of custom made mouthguards when the anterior angulation of dental model was increased during the thermoforming process. Materials & Methods: A total of 60 samples of mouthguard blanks were thermoformed on identical maxillary models under four anterior inclination conditions (n=4×15); control 0°, 15°, 30°, and 45° . Each mouthguard sample was measured, using an electronic calliper gauge, at 3 anatomical points (anterior labial sulcus, posterior occlusion and posterior lingual). Mouthguards were then CT scanned to give a visual representation of the surface thickness. Results: Data showed a significant difference (p < 0.005) in the anterior mouthguard thickness between the four levels of anterior inclination, with the 45° inclination producing the thickest mouthguards, increasing the mean anterior thickness by 75% (2.8mm, SD: 0.16) from the model on a flat plane (1.6mm, SD: 0.34). Anterior model inclination of 30o and 45o inclinations increased consistancies between the thickest and thinnest mouthguards in the anterior region of these sample groups. Conclusion: This study highlights the importance of standardising the thermoforming process, as this has a significant effect on the quality and material distribution of the resultant product. In particular, greater model inclination is advised as this optimises the thickness of the anterior sulcus of the mouthguard which may be more prominently at risk from sportrelated impact.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation into the relationship between thickness variations and manufacturing techniques of mouthguards.

BACKGROUND The aim of this study was to measure the finished thickness of a single identical 4-mm EVA mouthguard model from a large fabricated sample group and to evaluate the degree of material thinning and variations during the fabrication process. MATERIALS AND METHODS Twenty boxes were distributed to dental technician participants, each containing five duplicated dental models (n = 100), ...

متن کامل

Comparison of the Effect of ProTaper and Gates-Glidden Drills On the Remaining Root Dentin Thickness at the Coronal Region of the Root

Background and Aim: The purpose of this study was to evaluate residual dentin thickness of the root and the area of the canal lumen in the coronal region of the mesiobuccal and mesiolingual canals of the lower first molars after canal preparation with the common method of using hand files and Gates Glidden drills or ProTaper rotary files, by Spiral Ct-Scan. Materials and Methods: In this exp...

متن کامل

EFFECT OF CLINICAL IN FORMATION ON BRAIN CT SCAN IN T ERPRETATION: A BLIN DED DOUBLE CROSSOVER STUDY

Errors and variations in interpretation can happen in clinical imaging. Few studies have examined the biased effect of clinical information on reporting of brain CT scans. In a blinded double crossover design, we studied whether three radiologists were biased by clinical information when making CT scan diagnosis of the brain. Three consultant radiologists in three rounds with at least a one...

متن کامل

The effect of alendronate treatment on cortical thickness of the proximal femur in postmenopausal women

Background: Bisphosphonates (BPs) are used extensively for managing the osteoporosis. There are some controversies on atypical fractures of femur that associated with increase in cortical thickness (CT) and BPs&rsquo; use. In this study, the effects of alendronate consumption were studied on femoral CT as a predictor for atypical fracture. &nbsp; Methods: Forty nine post-menopausal women age...

متن کامل

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018