Predictive value of heidelberg retina tomograph parameters for the development of glaucoma in the European glaucoma prevention study.

نویسندگان

  • Stefano Miglior
  • Thierry Zeyen
  • Esther M Hoffmann
  • Valter Torri
  • Eliana Rulli
  • Irene Floriani
  • Davide Poli
  • Shakhsanam Aliyeva
  • José Cunha-Vaz
  • Norbert Pfeiffer
چکیده

PURPOSE To determine whether baseline Heidelberg Retina Tomograph (HRT) measurements of the optic disc are associated with the development of open-angle glaucoma (OAG) in individuals with ocular hypertension in the European Glaucoma Prevention Study (EGPS). DESIGN Retrospective analysis of a prospective, randomized, multicenter, double-masked, controlled clinical trial. METHODS There were 489 participants in the HRT Ancillary Study to the EGPS. Each baseline HRT parameter was assessed in univariate and multivariate proportional hazards models to determine its association with the development of OAG. Proportional hazards models were used to identify HRT variables that predicted which participants in the EGPS had developed OAG. Development of OAG was based on visual field and/or optic disc changes. RESULTS At a median follow-up time of about 5 years, 61 participants developed OAG. In multivariate analyses, adjusting for randomization arm, age, baseline IOP, central corneal thickness, pattern standard deviation, and HRT disc area, the following HRT parameters were associated with the development of OAG: the "outside normal limits" classification of the Frederick Mikelberg (FSM) discriminant function (hazard ratio [HR] 2.51, 95% confidence interval [CI]: 1.45-4.35), larger mean cup depth (HR 1.64, 95% CI: 1.21-2.23), cup-to-disc area ratio (HR 1.43, 95% CI: 1.14-1.80), linear cup-to-disc ratio (HR 1.43, 95% CI: 1.13-1.80), cup area (HR 1.33, 95% CI: 1.08-1.64), smaller rim area (HR 1.33, 95% CI: 1.07-1.64), larger cup volume (HR 1.30, 95% CI: 1.05-1.61), smaller rim volume (HR 1.25, 95% CI: 1.01-1.54), larger maximum cup depth (HR 1.18, 95% CI: 1.01-1.36), and cup shape measure (HR 1.18, 95% CI: 1.01-1.36). CONCLUSIONS Several baseline HRT parameters, alone or in combination with baseline clinical and demographic factors, were significantly associated with the development of OAG among the EGPS participants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Bayesian framework for glaucoma progression detection using Heidelberg Retina Tomograph images

Glaucoma, the second leading cause of blindness in the United States, is an ocular disease characterized by structural changes of the optic nerve head (ONH) and changes in visual function. Therefore, early detection is of high importance to preserve remaining visual function. In this context, the Heidelberg Retina Tomograph (HRT), a confocal scanning laser tomograph, is widely used as a researc...

متن کامل

Factors affecting the variability of the Heidelberg Retina Tomograph III measurements in newly diagnosed glaucoma patients.

PURPOSE To determine factors associated with the test-retest variability of optic nerve head (ONH) topography measurements with confocal scanning laser ophthalmoscopy (CSLO) in newly diagnosed glaucomatous patients. METHODS Consecutive patients with newly diagnosed primary open-angle glaucoma were prospectively enrolled. Patients presenting with any ocular disease other than glaucoma were exc...

متن کامل

Significance of the disc damage likelihood scale objectively measured by a non-mydriatic fundus camera in preperimetric glaucoma

PURPOSE To assess the correlation between the disc damage likelihood scale (DDLS) objectively measured by a non-mydriatic fundus camera, Heidelberg Retina Tomograph 3, and optic coherence tomography in preperimetric glaucoma. METHODS One-hundred-twenty-five patients with preperimetric primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (n=30) were included (mean age 58.9±15.9 ye...

متن کامل

[Relationship between standard automated perimetry and optic nerve head topography performed with the Heidelberg Retina Tomograph].

PURPOSE To determine the correlations between optic nerve head (ONH) parameters measured with the Heidelberg Retina Tomograph (HRT), and the main outcomes of standard automated perimetry (SAP) in normal, ocular hypertensive, glaucoma suspects and glaucomatous subjects. METHODS Four hundred and twenty-three patients were enrolled in the study and classified into four groups depending on baseli...

متن کامل

False negative results in glaucoma detection with Heidelberg Retina Tomograph II

PURPOSE To evaluate the rate of false negative results with the Heidelberg Retina Tomograph (HRT II) in a glaucoma practice. DESIGN Cross-sectional study. METHODS We analyzed the HRTs taken between October 2002 and October 2003 in our glaucoma clinic, and selected the patients who had a good quality image (SD < 40 mu) with a normal Moorfield's Regression Analysis (MRA). A masked independent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of ophthalmology

دوره 159 2  شماره 

صفحات  -

تاریخ انتشار 2015