Transosseous-equivalent rotator cuff repair: a systematic review on the biomechanical importance of tying the medial row.

نویسندگان

  • Nathan A Mall
  • Andrew S Lee
  • Jaskarndip Chahal
  • Geoffrey S Van Thiel
  • Anthony A Romeo
  • Nikhil N Verma
  • Brian J Cole
چکیده

PURPOSE Double-row and transosseous-equivalent repair techniques have shown greater strength and improved healing than single-row techniques. The purpose of this study was to determine whether tying of the medial-row sutures provides added stability during biomechanical testing of a transosseous-equivalent rotator cuff repair. METHODS We performed a systematic review of studies directly comparing biomechanical differences. RESULTS Five studies met the inclusion and exclusion criteria. Of the 5 studies, 4 showed improved biomechanical properties with tying the medial-row anchors before bringing the sutures laterally to the lateral-row anchors, whereas the remaining study showed no difference in contact pressure, mean failure load, or gap formation with a standard suture bridge with knots tied at the medial row compared with knotless repairs. CONCLUSIONS The results of this systematic review and quantitative synthesis indicate that the biomechanical factors ultimate load, stiffness, gap formation, and contact area are significantly improved when medial knots are tied as part of a transosseous-equivalent suture bridge construct compared with knotless constructs. Further studies comparing the clinical healing rates and functional outcomes between medial knotted and knotless repair techniques are needed. CLINICAL RELEVANCE This review indicates that biomechanical factors are improved when the medial row of a transosseous-equivalent rotator cuff is tied compared with a knotless repair. However, this has not been definitively proven to translate to improved healing rates clinically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

“trAnsosseous-equivAlent” rotAtor cuff repAir

tears remains challenging, because the high re-tear rate following rotator cuff repair is due to multiple factors. Aspects such as poor tendon biology, muscular fatty infiltration and retraction, and nonanatomical repairs ultimately lead to inferior repair biomechanics. Although many of these factors remain beyond the control of the surgeon, certain repair constructs have been shown to decrease...

متن کامل

Arthroscopic Double-Row Transosseous Equivalent Rotator Cuff Repair with a Knotless Self-Reinforcing Technique

BACKGROUND Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. METHODS The preferred technique for rotator cuff repair of the senior author was reviewed and described in a...

متن کامل

Biomechanical Performance of Medial Row Suture Placement Relative to the Musculotendinous Junction in Transosseous Equivalent Suture Bridge Double-Row Rotator Cuff Repair.

PURPOSE To compare the biomechanical performance of medial row suture placement relative to the musculotendinous junction (MTJ) in a cadaveric transosseous equivalent suture bridge (TOE-SB) double-row (DR) rotator cuff repair (RCR) model. METHODS A TOE-SB DR technique was used to reattach experimentally created supraspinatus tendon tears in 9 pairs of human cadaveric shoulders. The medial row...

متن کامل

Arthroscopic rotator cuff repairs: an anatomic and biomechanical rationale for different suture-anchor repair configurations.

The goal of rotator cuff repairs is to achieve high initial fixation strength, minimize gap formation, maintain mechanical stability under cyclic loading, and optimize the biology of the tendon-bone interface until the cuff heals biologically to the bone. We have seen an evolution in our approaches to fixing rotator cuff tears from open to mini-open to all arthroscopic. In our arthroscopic tech...

متن کامل

Double-row rotator cuff repair yields improved tendon structural integrity, but no difference in clinical outcomes compared with single-row and triple-row repair: a systematic review

Rush LN, et al. JISAKOS 2017;2:260–268. doi:10.1136/jisakos-2016-000069. Copyright © 2017 ISAKOS AbstrAct Importance Techniques for arthroscopic rotator cuff repair are rapidly evolving. Single-row (SR) and doublerow (DR) repair techniques have been well described, but recent studies have suggested the biomechanical superiority of transosseous-equivalent (TOE) DR repairs and triple-row (TR) rep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 29 2  شماره 

صفحات  -

تاریخ انتشار 2013