Multilaboratory comparison of hepatitis C virus viral load assays.

نویسندگان

  • A M Caliendo
  • A Valsamakis
  • Y Zhou
  • B Yen-Lieberman
  • J Andersen
  • S Young
  • A Ferreira-Gonzalez
  • G J Tsongalis
  • R Pyles
  • J W Bremer
  • N S Lurain
چکیده

We report a multilaboratory evaluation of hepatitis C virus (HCV) viral load assays to determine their linear range, reproducibility, subtype detection, and agreement. A panel of HCV RNA samples ranging in nominal concentration from 1.0 to 7.0 log10 IU/ml was constructed by diluting a clinical specimen (genotype 1b). Replicates of the panel were tested in multiple laboratories using the Abbott TaqMan analyte-specific reagent (Abbott reverse transcription-PCR [RT-PCR]), Roche TaqMan RUO (Roche RT-PCR), Roche Amplicor Monitor HCV 2.0 (Roche Monitor), and Bayer VERSANT HCV RNA 3.0 (Bayer bDNA) assays. Bayer bDNA-negative specimens were tested reflexively using the Bayer VERSANT HCV RNA qualitative assay (Bayer TMA). Abbott RT-PCR and Roche RT-PCR detected all 28 replicates with a concentration of 1.0 log10 IU/ml and were linear to 7.0 log10 IU/ml. Roche Monitor and Bayer bDNA detected 27 out of 28 and 13 out of 28 replicates, respectively, of 3.0 log10 IU/ml. Bayer TMA detected all seven replicates with 1.0 log10 IU/ml. Bayer bDNA was the most reproducible of the four assays. The mean viral load values for panel members in the linear ranges of the assays were within 0.5 log10 for the different tests. Eighty-nine clinical specimens of various genotypes (1 through 4) were tested in the Bayer bDNA, Abbott RT-PCR, and Roche RT-PCR assays. For Abbott RT-PCR, mean viral load values were 0.61 to 0.96 log10 greater than the values for Bayer bDNA assay for samples with genotype 1, 2, or 3 samples and 0.08 log10 greater for genotype 4 specimens. The Roche RT-PCR assay gave mean viral load values that were 0.28 to 0.82 log10 greater than those obtained with the Bayer bDNA assay for genotype 1, 2, and 3 samples. However, for genotype 4 samples the mean viral load value obtained with the Roche RT-PCR assay was, on average, 0.15 log10 lower than that of the Bayer bDNA. Based on these data, we conclude that the sensitivity and linear range of the Abbott and Roche RT-PCR assays enable them to be used for HCV diagnostics and therapeutic monitoring. However, the differences in the viral load values obtained with the different assays underscore the importance of using one assay when monitoring response to therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Relationship between Hepatitis C Genotypes and Viral Load: a study on hepatitis C patients in Kerman, Iran using Real-time PCR

Abstract Background: Distribution of hepatitis C virus genotypes varies geographically and can be associated with clinical aspects. The virus has six major genotypes and eleven sub-genotypes. According to the recent studies, in hepatitis C patients, treatment duration and ribavirin dosage should be determined based on the type of virus genotype. Be...

متن کامل

Comparison of PEG Interferon Loaded and non-Loaded Iron Oxide Nanoparticles on Hepatitis C Virus Replication in Cell Culture System

Background and Aims: Iron oxide nanoparticles are among the most effective tools which can replace current medical techniques for diagnosis and treatment of various diseases. Hepatitis C infection is one of the main health problems in the world, affecting around 3% of the world's population. This infection can develop into liver cirrhosis and liver cancer over the time in 80% of patients. In t...

متن کامل

Epidemiologic Study of Hepatitis C Virus Transmission in Lorestan Province (2011-14)

ABSTRACT        Background and Objective: This study was conducted to evaluate epidemiology of risk factors for hepatitis C virus (HCV) transmission, and determine the association of its genotypes with viral load and response to treatment in patients referred to the Infectious Disease Clinic of Khorramabad.         Methods...

متن کامل

Investigation of Human Leukocyte Antigen (HLA) Class I and II Alleles and Hepatitis C Virus (HCV) Genotypes in Patients Infected with HCV

Hepatitis C virus (HCV) is a major public health problem with more than 130-180 million people infected worldwide. Several studies in different populations have reported the association of human leukocyte antigen (HLA) genotypes, and HCV viral load, and genotypes. The aim of this study was to investigate a possible association between HLA class I and II alleles in HCV-infected patients and heal...

متن کامل

Performance of the novel Qiagen artus QS-RGQ viral load assays compared to that of the Abbott RealTime system with genetically diversified HIV and hepatitis C Virus plasma specimens.

We compared two novel Qiagen QS-RGQ viral load assays with the established Abbott RealTime assays on a highly diversified panel of 121 human immunodeficiency virus (HIV) and 107 hepatitis C virus (HCV) specimens. The quantifications correlated well for all HIV and HCV types, but Qiagen yielded higher HCV concentrations than Abbott, predominantly in genotypes 4 and 5.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 44 5  شماره 

صفحات  -

تاریخ انتشار 2006