Incidence of microemboli and correlation with platelet inhibition in aneurysmal flow diversion.

نویسندگان

  • M R Levitt
  • B V Ghodke
  • D K Hallam
  • L N Sekhar
  • L J Kim
چکیده

Flow-diverting stents have been associated with embolic and hemorrhagic complications, but the rate of procedure-related microemboli is unknown. Using transcranial Doppler sonography, we measured the rate of microemboli in 23 patients treated with flow-diverting stents. Patients received preprocedural dual antiplatelet medications and intraprocedural heparinization. Point-of-care platelet reactivity testing was performed before the procedure, and nonresponders (>213 P2Y12/ADP receptor reactivity units) received additional thienopyridine. Transcranial Doppler sonography was performed within 12-24 hours. Microemboli were detected in 3 patients (13%), 2 of whom were initially nonresponders. There was no association between the presence of microemboli and procedural or neurologic complications, aneurysm size, number of stents, or procedure time. Eight procedures (34.8%) required additional thienopyridine for inadequate platelet inhibition, and 3 required further treatment for persistent nonresponse to point-of-care platelet reactivity testing. There were 6 technical and 2 postoperative complications; none were associated with inadequate platelet inhibition or microemboli. The combination of routine point-of-care platelet reactivity testing and postprocedural microembolic monitoring may help identify patients at risk for thromboembolic complications after flow-diverting stents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Topical Review Flow Diversion for Intracranial Aneurysms A Review

The introduction of flow diverters for treatment of intracranial aneurysms represents a major paradigm shift in the treatment of these lesions. The theoretical hallmark of flow diverters is the treatment of the diseased segment harboring the aneurysm instead of treating the aneurysm itself. Flow diverters are designed to induce disruption of flow near the aneurysm neck while preserving flow int...

متن کامل

Flow diversion for intracranial aneurysms: a review.

The introduction of flow diverters for treatment of intracranial aneurysms represents a major paradigm shift in the treatment of these lesions. The theoretical hallmark of flow diverters is the treatment of the diseased segment harboring the aneurysm instead of treating the aneurysm itself. Flow diverters are designed to induce disruption of flow near the aneurysm neck while preserving flow int...

متن کامل

Quantitative Immunophemotyping of Platelet Surface Glycoproteins among Iranian Patients with Bernard-Soulier Syndrome

Background: Bernard-Soulier syndrome is a rare inherited bleeding disease caused by quantitative or qualitative defect of GPIb/IX/V, a platelet complex that binds the Von Willebrand factor. The expression of GPIb-IX-V complex can be evaluated by flow cytometry and confirmed by the absence of ristocetin-induced platelet aggregation in platelet-rich plasma. The main aim of the present study was t...

متن کامل

Numerical simulation of flow in a fishway of Karkheh-Hamidieh diversion dam and environmental considerations to investigate possibility of fishway use in Mazandaran Province

Pool and weir is a type of fishway that provides a route for fish to migrate to damupstream. The effective parameters for fish swimming include velocity, water depth andturbulence. Several rubber dams have been under construction in Mazandaran Province, butthe necessary structures have not been built around them yet. When constructing these rubberdams, numerical models can be used to evaluate f...

متن کامل

The eJournal of the European Society of Minimally Invasive Neurological Therapy The ESMINT Retrospective Analysis of Delayed Aneurysm Ruptures after flow diversion (RADAR) study

Introduction: Rupture following flow diversion treatment has been reported as a complication of this technique. The aim of this survey was to investigate the efficacy of flow diversion by retrospectively analysing the rate of delayed ruptures in all centres using this technology. Methods: A questionnaire based survey about thromboembolic and haemorrhagic complications related to flow diversion ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 34 12  شماره 

صفحات  -

تاریخ انتشار 2013