A comparative in vitro study of the frictional characteristics of two types of self-ligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures.
نویسندگان
چکیده
The aim of this in vitro study was to investigate the frictional characteristics of two types of self-ligating brackets ('A' Company Damon SL and Adenta Time brackets) and two types of pre-adjusted edgewise brackets (TP Tip-Edge and 'A' Company Standard Twin brackets). The test brackets were glued to steel bars and aligned using a preformed jig. Five combinations of archwire size and material were used (0.014-inch nickel titanium, 0.0175-inch multistrand stainless steel, 0.016 x 0.022-inch nickel titanium, 0.016 x 0.022-inch stainless steel and 0.019 x 0.025-inch stainless steel wires). The wires were drawn through the brackets and the frictional resistance was measured using an Instron 1193 testing machine. The data were analysed using a one-way analysis of variance and Scheffe's multiple comparison of means test. The results revealed that the Damon brackets demonstrated the lowest friction for all dimensions of test wires followed by the Time bracket. The 'A' Company Standard Twin brackets produced the highest friction with all wire dimensions tested, followed by the Tip-Edge bracket. With all brackets the 0.016 x 0.022-inch nickel titanium wires produced a higher frictional resistance than the 0.016 x 0.022-inch stainless steel wires. The results indicate that these self-ligating brackets produce less frictional resistance than elastomerically-tied pre-adjusted edgewise brackets.
منابع مشابه
Frictional Properties of Self-Ligating Brackets and Low-Friction Ligatures
Problem statement: To evaluate the frictional forces generated by five different orthodontic brackets when used in combination with stainless steel and NiTi archwires in dry conditions at physiological temperature. Approach: Five different types of maxillary canine brackets (Damon 3 MX, Step, Quick, Sprint, Mini Mono) with a slot size 0.022 inch were coupled with 0.016” and 0.019”×0.025” stainl...
متن کاملEfficacy of Super Slick elastomeric modules in reducing friction during sliding: a comparative in vitro study.
AIM To evaluate and compare the frictional resistance produced by Super Slick modules during sliding with four different types of brackets and four ligature types both in conventional and figure-of-8 ligation method with saliva as lubricant. MATERIALS AND METHODS The frictional resistance was evaluated by using four different ligatures on 0.019" × 0.025" stainless steel (SS) archwires using f...
متن کاملEvaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study
Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...
متن کاملForces released during sliding mechanics with passive self-ligating brackets or nonconventional elastomeric ligatures.
INTRODUCTION The aim of this study was to evaluate the frictional forces generated by 4 types of passive stainless steel self-ligating brackets (SLBs) and by nonconventional elastomeric ligatures (NCEL) and conventional elastomeric ligatures (CEL) during sliding mechanics. METHODS An experimental model consisting of 5 aligned stainless steel 0.022-in brackets was used to assess frictional for...
متن کاملEvaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.
AIM The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS). METHODS An experimental model which consisted of 5 aligned stainless steel 0.022...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of orthodontics
دوره 20 5 شماره
صفحات -
تاریخ انتشار 1998