Fault ride-through capability of a DFIG in isolated grids employing DVR and supercapacitor energy storage
نویسندگان
چکیده
In order to utilize Doubly Fed Induction Generators (DFIGs) as primary power source in an isolated system, they should be able to regulate the voltage and frequency of the system as well as ride-through faults. This paper proposes a new control strategy for a DFIG operating in an isolated power system, accomplished by a Dynamic Voltage Restorer (DVR) and a Supercapacitor Energy Storage System (SCESS), in order to ride through symmetrical and asymmetrical faults. During faults, the DFIG continues to operate normally, while the active power mismatch is handled by the SCESS. In particular, during asymmetrical faults, the DFIG and the DVR are properly controlled in order to feed the non-faulty phases uninterruptedly. When integrated in a power system with conventional synchronous generators, the proposed control strategy improves the Fault Ride-Through (FRT) capability of a DFIG, while providing frequency and voltage support to the system throughout the fault duration. Thus, the transient stability of the power system is significantly improved. The effectiveness of the proposed control method under different fault conditions is verified by detailed simulation results. 2014 Elsevier Ltd. All rights reserved.
منابع مشابه
Low Voltage Ride-Through Capability Improvement of Doubly Fed Induction Generator using DVR and SMES
Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...
متن کاملOptimal Intelligent Control of Plug-in Fuel Cell Electric Vehicles in Smart Electric Grids
In this paper, Plug-in Fuel Cell Electric Vehicle (PFCEV) is considered with dual power sources including Fuel Cell (FC) and battery Energy Storage. In order to respond to a transient power demand, usually supercapacitor energy storage device is combined with fuel cell to create a hybrid system with high energy density of fuel cell and the high power density of battery. In order to simulate the...
متن کاملEnhancement of Fault Ride through Capability of a Wind Driven Dfig Connected to the Grid
Enhancement of fault ride-through (FRT) capability and subsequent improvement of rotor speed stability of wind farms equipped with doubly fed induction generator (DFIG) is the objective of this paper. The objective is achieved by employing a novel FRT scheme with suitable control strategy. The proposed FRT scheme, which is connected between the rotor circuit and dc link capacitor in parallel wi...
متن کاملLow Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage
In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...
متن کاملComparative Study of the Performance of Static Synchronous Compensator, Series Compensator and Compensator /Battery Integrated to a Fixed Wind Turbine (RESEARCH NOTE)
This paper studies the interest of the integration of battery energy storage with Static Synchronous Compensator (STATCOM) for improving the low voltage ride through capability (LVRT) of a fixed speed wind turbine connected to the grid. For this reason and by applying a grid fault, a comparison is made between integrating the SSSC, the STATCOM and the STATCOM with battery energy storage. The sy...
متن کامل