Transthoracic measurement of left coronary artery flow reserve improves the diagnostic value of routine dipyridamole-atropine stress echocardiogram

نویسندگان

  • Jarosław D. Kasprzak
  • Paulina Wejner-Mik
  • Aria Nouri
  • Ewa Szymczyk
  • Maria Krzemińska-Pakuła
  • Piotr Lipiec
چکیده

INTRODUCTION We hypothesized that coronary flow reserve (CFR) in the left anterior descending artery (LAD) can be effectively measured during an accelerated dipyridamole-atropine stress echocardiography (DASE) protocol to improve the diagnostic performance of the test. MATERIAL AND METHODS In 64 patients with suspected or known coronary artery disease scheduled for coronary angiography DASE with concomitant CFR measurement in LAD was performed. RESULTS Coronary flow reserve measurement and calculation were feasible in 83% of patients. The positive predictive value of undetectable LAD flow was 81% for severe LAD disease. Measured values of CFR were in the range 1.3-4.1 (mean: 2.2 ±0.7). Significantly lower CFR was found in patients with LAD disease (1.97 ±0.62 vs. 2.55 ±0.57, p = 0.0015). The optimal cutoff for detecting ≥ 50% stenosis was CFR ≤ 2.1 (ROC AUC 0.776), corresponding with 68% sensitivity and 84% specificity. In patients with negative DASE results 67% of patients with LAD disease had abnormal CFR, whereas in patients with a positive DASE result 92% of patients with normal LAD had normal CFR. The DASE diagnostic accuracy for the detection of coronary artery disease (CAD) increased from 75% to 85% when CFR measurement was added to wall motion abnormality (WMA) analysis. No test with both abnormalities was false positive for the detection of coronary disease. CONCLUSIONS Incorporation of CFR measurement into WMA-based stress echocardiography is feasible even in an accelerated DASE protocol and can be translated into an approximate gain of 10% in overall test accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography.

OBJECTIVE To investigate transthoracic Doppler echocardiography in the identification of coronary artery bypass graft (CABG) flow for assessing graft patency. DESIGN The initial study group comprised 45 consecutive patients with previous CABG undergoing elective cardiac catheterisation for recurrent ischaemia. The Doppler variables best correlated with angiographic graft patency were then tes...

متن کامل

Coronary flow reserve in stress-echo lab. From pathophysiologic toy to diagnostic tool

The assessment of coronary flow reserve by transthoracic echocardiography has recently been introduced into clinical practice with gratifying results for the diagnosis of left anterior descending artery disease simultaneously reported by several independent laboratories. This technological novelty is changing the practice of stress echo for 3 main reasons. First, adding coronary flow reserve to...

متن کامل

Coronary flow velocity reserve in three major coronary arteries by transthoracic echocardiography for the functional assessment of coronary artery disease: a comparison with fractional flow reserve.

AIMS Coronary flow velocity reserve (CFVR) measurement in three major coronary arteries by transthoracic echocardiography is a promising and non-invasive method for detecting myocardial ischaemia. Its value when compared with fractional flow reserve (FFR) is unknown. Our aim was to determine the diagnostic accuracy of CFVR in three major coronary arteries for detecting ischaemia compared with F...

متن کامل

Coronary flow: a new asset for the echo lab?

Non-invasive imaging of coronary blood flow by transthoracic Doppler echocardiography is an emerging diagnostic tool to study the left anterior descending (LAD) and posterior descending (PD) coronary arteries. With this new clinical application of echocardiography, we can directly measure changes in coronary flow velocity reserve (CFVR) at the very beginning of the ischaemic cascade, instead of...

متن کامل

New noninvasive method for coronary flow reserve assessment: contrast-enhanced transthoracic second harmonic echo Doppler.

BACKGROUND We tested the hypothesis that blood flow velocity could be recorded in the left anterior descending coronary artery (LAD) during transthoracic echocardiography by use of second harmonic echo Doppler modality along with contrast enhancement (intravenous Levovist) at rest and after pharmacologically induced maximal vasodilation to assess coronary flow reserve (CFR) with a totally nonin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2013