Endovascular repair of abdominal aortic aneurysms with reverse taper neck anatomy using the Endurant stent-graft: analysis of stent-graft oversizing.

نویسندگان

  • Bibombe P Mwipatayi
  • Alarick Picardo
  • Jackie Wong
  • Shannon D Thomas
  • Vikram Vijayan
چکیده

PURPOSE To evaluate endovascular repair of infrarenal abdominal aortic aneurysms (AAA) using the Endurant stent-graft and compare the outcomes of patients with different neck anatomies, particularly as pertains to stent-graft oversizing. METHODS A retrospective review was conducted of 75 consecutive patients (69 men; mean age 75 years) undergoing endovascular AAA repair using the Endurant Stent Graft System from December 2008 to September 2011. The mean AAA size was 57±10 mm (range 51-92), with a mean proximal neck length of 33±10 mm (9-127) and a mean infrarenal neck angulation of 25°±15° (0°-91°). Patients were stratified according to neck anatomy [reverse taper (n=22) vs. inside (n=44) and outside (n=9) the Instructions for Use (IFU) criteria]. Standard safety and efficacy outcome measures were augmented by measurements of the percent oversizing at the proximal and distal neck and volumes of the proximal neck and stent-graft. RESULTS Technical success was 100% in all groups, with no early or late type Ia endoleak detected in any group. Procedure time, contrast volumes, and radiation dosages were comparable in all groups. The reverse taper neck group had stent-graft diameters and volumes that were significantly larger (p=0.007) than the other groups. The proximal neck oversizing of the endograft was significantly greater (p=0.008) in the reverse taper neck group (42.9%±17.5%) compared to the within the IFU group (30.1%±11.7%). Over a mean follow-up of 20 months (range 14-46), there were no aneurysm-related deaths and 9 type II endoleaks (5 in the reverse taper neck group; overall, 3 were treated and 6 resolved spontaneously). The outside the IFU group suffered no endoleak of any type and had no secondary interventions. CONCLUSION The Endurant stent-graft can be utilized with acceptable results in more challenging neck anatomies, such as those with a reverse taper, as long as there is adequate oversizing of the stent-graft.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Late Type 3b Endoleak with an Endurant Endograft

Endovascular stent grafting with different commercially available stent graft systems is widely applied for the treatment of abdominal aortic aneurysms with high success rates in the current era. Various types of endoleaks are potential complications of the procedure. They usually occur in the early period. In this report, we present type 3b endoleak occurring 14 months after a successful endov...

متن کامل

Troubleshooting techniques for the EndurantTM device in endovascular aortic aneurysm repair

Endovascular aortic aneurysm repair with the Endurant™ stent-graft system has been shown to be safe and effective in high-risk surgical patients with complex suprarenal and/or infrarenal abdominal aortic aneurysm anatomy. The wireformed M-shaped stent architecture and proximal springs with anchoring pins theoretically permit optimal sealing in shorter and more angulated proximal aneurysm necks ...

متن کامل

Ventana fenestrated stent-graft system for endovascular repair of juxtarenal aortic aneurysms.

PURPOSE To describe the initial use of an off-the-shelf fenestrated stent-graft system for endovascular repair of juxtarenal abdominal aortic aneurysms. TECHNIQUE The off-the-shelf Ventana fenestrated stent-graft system consists of a 25-mm IntuiTrak self-expanding bifurcated stent-graft implanted at the aortic bifurcation. A Ventana self-expanding fenestrated proximal extension stent-graft is...

متن کامل

Endovascular repair of abdominal aortic aneurysm with severely angulated neck and tortuous artery access: case report and literature review

BACKGROUND Endovascular aneurysm repair has revolutionized the therapeutic strategy for abdominal aortic aneurysm. However, hostile proximal aneurysmal neck and tortuosity of access vessels remain challenges in selecting optimal stent-grafts in abdominal aortic aneurysms with difficult anatomy. CASE PRESENTATION A 65-year-old woman complained of intermittent abdominal pain for one week. Compu...

متن کامل

Application of physician-modified fenestrated stent graft in urgent endovascular repair of abdominal aortic aneurysm with hostile neck anatomy

BACKGROUND This study aimed to evaluate the feasibility and effectiveness of the Gore Excluder aortic stent graft (WL Gore & Associates, Inc., Flagstaff, AZ) using the C3 Delivery System after physician modification of fenestration for the urgent treatment of patients with abdominal aortic aneurysm showing hostile neck anatomy. CASE SUMMARY Three urgent cases of abdominal aortic aneurysm with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists

دوره 20 4  شماره 

صفحات  -

تاریخ انتشار 2013