A method for delivering accurate and uniform radiation dosages to the head and neck with asymmetric collimators and a single isocenter.
نویسندگان
چکیده
PURPOSE To investigate the use of asymmetric collimators and a single isocenter for delivering a uniform, accurate dose of radiation to the head, neck, and supraclavicular lymph nodes. METHODS AND MATERIALS A linear accelerator with a pair of asymmetric collimators is required for this technique. An isocenter was placed at the junction of the lateral head and neck fields and the anterior supraclavicular field. The asymmetric collimators were set longitudinally, by collimator rotation if necessary. The collimators split the radiation beam to all portals. Dose uniformity was measured at the junction with films in solid-water phantoms. RESULTS Film dosimetry showed a uniform dose at the junction without hot or cold regions. A digital display tolerance of +/- 1.0 mm for a field size maintained an acceptable uniform dose (+/- 5% dose variation) at the junction. The single isocenter and asymmetric collimators reduced field setup time by half. No table rotation was required to match fields. CONCLUSION The asymmetric collimators lead to easy and accurate patient setup. The absence of the trapezoid effect resulted in the complete coverage of the submandibular and cervical nodes without any hot spots.
منابع مشابه
Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)
Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...
متن کاملAssessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification
Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...
متن کاملDevelopment of a prototype stereotactic collimation assembly for Neptun 10 PC linac
Background: A set of hardware stereotactic radiosurgery is designed and constructed. The scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 MV Neptun 10 PC linac. Materials and methods: One collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. Beam data, suc...
متن کاملQuantification of Partial Volume Effects in Salivary Glands SPECT Images after Radiation Therapy of Head and Neck Tumors
Introduction: Radical radiation therapy of head and neck cancers may injure the salivary glands and reduce their function. Single-photon emission computed tomography (SPECT) images maybe used to evaluate function post-therapy. However, accurate quantification is hindered by the partial volume effects (PVEs). The present study involved the introduction of a PVEs quantif...
متن کاملComparison of measured and Monte Carlo calculated dose distributions from “circular collimators” for radiosurgical beams
Background: Stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. A dosimetry study was performed for Elekta ‘Synergy S ’ as a dedicated Stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the BEAM/EGS4...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of radiation oncology, biology, physics
دوره 32 3 شماره
صفحات -
تاریخ انتشار 1995