Correlation of Relative Dispersion Analysis and Other High Pass Resolution Perimetry Indices with Standard Threshold Perimetry

نویسندگان

  • MICHELE IESTER
  • MICHELE ALTIERI
  • CARLO E. TRAVERSO
  • PAOLO CAPRIS
  • MARIO ZINGIRIAN
چکیده

Purpose: Relative dispersion analysis (RDA), a new high pass resolution perimetry (HRP) index, appears to capture a novel aspect of visual field abnormality. The aim of this study was to evaluate the correlation of RDA and other HRP indices with the Humphrey perimeter parameters. Methods: Fifty-six eyes were randomly recruited from among patients at the authors’ clinic. Twenty-nine eyes were classified as glaucomatous (high intraocular pressure, abnormal visual field and/or optic disc) and 27 as ocular hypertensives (high intraocular pressure, normal visual field, normal optic disc defect). All the subjects were examined with the Humphrey perimeter, program 30-2, and HRP. The HRP data were also analyzed with the RDA program. Statistical analysis was performed with Student’s t test, Pearson’s r correlation coefficient, the Mann-Whitney non-parametric test and Spearman’s correlation coefficient when appropriate. Results: A strong correlation was found between the standard threshold perimetry indices and those of HRP. For the entire sample, the following significant correlations were found between the RDA index (DI) and all the HRP indices (p<0.001), and corrected pattern standard deviation (p<0.05), pattern standard deviation (p<0.01) and short-term fluctuation (p<0.05). No correlation was found with the mean deviation. Conclusions: The DI of HRP is theoretically capable of detecting localized dishomogeneity of retinal sensitivity. These data support this hypothesis. However, further studies are needed before this index can be applied clinically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative dispersion analysis enhances perimetric sensitivity

Objective identification of minor visual field defects is problematic. A possible solution is to examine spatial correlations by means of relative dispersion analysis, a tool of fractal analysis. We studied patients with glaucoma, previous optic neuritis, chiasmal compression and lesions of the brain hemispheres, using high-pass resolution perimetry. One-hundred visual field records were drawn ...

متن کامل

1235 High-pass resolution perimetry vs static threshold perimetry in advanced primary open-angle glaucoma

PURPOSE: To compare Static Threshold Perimetry (Humphrey 30.2) with High-pass Resolution Perimetry (Ophthimus) for the assessment of Visual Field W.F.) defects in uatients with advanced glaucomatous damage. METHODS: Patient selection criteria: Primary Open-angle Glaucoma, advanced V.F. damage (MD > 5 dB) visual acuity > 20/70. previous experience in V.F. testing: 38 eyes were selected for the s...

متن کامل

Variability of high-pass resolution perimetry in normals and patients with idiopathic intracranial hypertension.

High-pass resolution perimetry, or the "ring test," is a recently developed type of acuity perimetry. To determine its test-retest variability, we studied 10 normals and 10 patients with idiopathic intracranial hypertension (IIH) by testing both eyes four separate times. There was no increase in variability from the center out to 21 degrees of visual field eccentricity. However, there was a sig...

متن کامل

[Agreement and correlation between the frequency doubling perimetry and the blue-yellow perimetry in glaucoma: no support for selective damage].

PURPOSE To test the agreement and correlation between the frequency doubling technology and the short wavelength perimetry in glaucoma. METHODS Glaucoma patients were selected from the Glaucoma Sector of CEROF - Universidade Federal de Goiás, and then underwent frequency doubling technology and short wavelength perimetry examinations in both eyes (if eligible) on the same day in a random sequ...

متن کامل

Comparison between Tendency-Oriented Perimetry (TOP) and octopus threshold perimetry.

OBJECTIVE To compare the results obtained by a new ultra-short automated perimetry test known as Tendency-Oriented Perimetry (TOP), which is an algorithm based on estimation of thresholds from information gathered from adjacent points with those obtained by a standard bracketing approach. TOP is designed to save up to 1/5 of the time taken by standard strategy by presenting each stimulus once o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999