The impedance cardiogram recorded through two electrocardiogram/defibrillator pads as a determinant of cardiac arrest during experimental studies.

نویسندگان

  • Nick Alexander Cromie
  • John Desmond Allen
  • Colin Turner
  • John McC Anderson
  • A A Jennifer Adgey
چکیده

OBJECTIVE Laypersons are poor at emergency pulse checks (sensitivity 84%, specificity 36%). Guidelines indicate that pulse checks should not be performed. The impedance cardiogram (dZ/dt) is used to assess stroke volume. Can a novel defibrillator-based impedance cardiogram system be used to distinguish between circulatory arrest and other collapse states? DESIGN Animal study. SETTING University research laboratory. SUBJECTS Twenty anesthetized, mechanically ventilated pigs, weight 50-55 kg. INTERVENTIONS Stroke volume was altered by right ventricular pacing (160, 210, 260, and 305 beats/min). Cardiac arrest states were then induced: ventricular fibrillation (by rapid ventricular pacing) and, after successful defibrillation, pulseless electrical activity and asystole (by high-dose intravenous pentobarbitone). MEASUREMENTS AND MAIN RESULTS The impedance cardiogram was recorded through electrocardiogram/defibrillator pads in standard cardiac arrest positions. Simultaneously recorded electro- and impedance cardiogram (dZ/dt) along with arterial blood pressure tracings were digitized during each pacing and cardiac arrest protocol. Five-second epochs were analyzed for sinus rhythm (20 before ventricular fibrillation, 20 after successful defibrillation), ventricular fibrillation (40), pulseless electrical activity (20), and asystole (20), in two sets of ten pigs (ten training, ten validation). Standard impedance cardiogram variables were noncontributory in cardiac arrest, so the fast Fourier transform of dZ/dt was assessed. During ventricular pacing, the peak amplitude of fast Fourier transform of dZ/dt (between 1.5 and 4.5 Hz) correlated with stroke volume (r2 = .3, p < .001). In cardiac arrest, a peak amplitude of fast Fourier transform of dZ/dt of < or = 4 dB x ohm x rms indicated no output with high sensitivity (94% training set, 86% validation set) and specificity (98% training set, 90% validation set). CONCLUSIONS As a powerful clinical marker of circulatory collapse, the fast Fourier transformation of dZ/dt (impedance cardiogram) has the potential to improve emergency care by laypersons using automated defibrillators.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the impedance cardiogram recorded by an automated external defibrillator during clinical cardiac arrest.

OBJECTIVE To assess the impedance cardiogram recorded by an automated external defibrillator during cardiac arrest to facilitate emergency care by lay persons. Lay persons are poor at emergency pulse checks (sensitivity 84%, specificity 36%); guidelines recommend they should not be performed. The impedance cardiogram (dZ/dt) is used to indicate stroke volume. Can an impedance cardiogram algorit...

متن کامل

The transthoracic impedance cardiogram is a potential haemodynamic sensor for an automated external defibrillator.

AIMS The American Heart Association has endorsed the concept of Public Access Defibrillation. However, there have been reports of inappropriate direct current shocks from automatic external defibrillators. The specificity of automatic external defibrillators for shockable rhythms may be improved by the incorporation of a haemodynamic sensor. METHODS AND RESULTS This study examined the use of ...

متن کامل

Study of Transthoracic Impedance Cardiogram for Assessment of Cardiac Hemodynamics in Atrial Fibrillation Patents

This study aims to test the usability of the transthoracic impedance cardiogram (ICG) for assessment of the quality of myocardial contractions in atrial fibrillation (AFIB) vs. sinus rhythm (SR), using signals recorded via defibrillation pads during external cardioversion (ECV). Data from 88 patients with persistent AFIB who received planned ECV are processed. AFIB is treated with cardioverter/...

متن کامل

Effect of mitral valvular regurgitation on transthoracic impedance cardiogram.

Mitral valvular regurgitation consistently modified the wave form of the first derivative of the transthoracic impedance cardiogram. The transthoracic impedance cardiogram was recorded in 23 control subjects (group 1), and 23 patients with isolated mitral regurgitation (group 2). Simultaneous transthoracic impedance cardiogram, electrocardiogram, and mitral valve echocardiograms in group 1 show...

متن کامل

Effect of aortic valvular regurgitation upon the impedance cardiogram.

The first derivative thoracic impedance cardiogram, phonocardiogram, and electrocardiogram were recorded in three groups of 22 subjects each. In Group 1 (control), simultaneous impedance cardiogram, phonocardiogram, and aortic valve echocardiograms showed that the X point of the impedance cardiogram occurred synchronously with the aortic second heart sound and with echocardiographic aortic valv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Critical care medicine

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 2008