MR imaging of joints: analytic optimization of GRE techniques at 1.5 T.

نویسندگان

  • L Yao
  • S Sinha
  • L L Seeger
چکیده

To clarify the choice of imaging parameters for optimal gradient-recalled echo MR scanning of joints, we analyzed the behavior of contrast-to-noise and signal-to-noise ratios for spoiled (i.e., fast low-angle shot [FLASH] or spoiled GRASS) and steady-state (i.e., gradient-recalled acquisition in the steady state [GRASS] or fast imaging with steady precession) techniques at 1.5 T. The analysis is based on tissue characteristics derived from spin-echo measurements of hyaline cartilage and synovial fluid signal in the patellofemoral joints of 11 volunteers. Separate analysis of contrast-to-noise and signal-to-noise ratios for multiplanar (long TR) acquisitions shows that these parameters are each improved compared with single-slice methods. At TRs greater than 250 msec, there is no significant difference in the contrast behavior of FLASH and GRASS. For optimal contrast-to-noise ratio (synovial fluid-cartilage), the best multiplanar sequence (for TE less than 23 msec) is with a short TE and a large flip angle (e.g., 400/9/73 degrees [TR/TE/flip angle]). If a single-scan or three-dimensional technique is desired, than a GRASS sequence at minimal TR and TE and intermediate flip angle (18/9/32 degrees) is best. For optimal signal-to-noise ratio (for both synovial fluid and hyaline cartilage), the best multiplanar sequence uses a short TE and an intermediate flip angle (e.g., 400/9/30 degrees). If a short TR, high signal-to-noise technique is desired, then GRASS (18/9/13 degrees) is superior to FLASH.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiecho IDEAL gradient-echo water-fat separation for rapid assessment of cartilage volume at 1.5 T: initial experience.

Institutional review board approval and informed consent were obtained for this HIPAA-compliant study. The purpose was to prospectively compare multiecho iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) gradient-echo (GRE) magnetic resonance (MR) imaging with three-dimensional fat-suppressed (FS) spoiled GRE (SPGR) MR imaging to evaluate the arti...

متن کامل

Lateral ulnar collateral ligament of the elbow: optimization of evaluation with two-dimensional MR imaging.

PURPOSE To compare, in a cadaveric model, magnetic resonance (MR) imaging techniques with differing contrast and spatial resolution properties in the evaluation of disruption of the lateral ulnar collateral ligament (LUCL) at the elbow. MATERIALS AND METHODS LUCL tears were surgically created in eight of 28 cadaveric elbow specimens. All specimens underwent 1.5-T MR imaging with the following...

متن کامل

Mapping of hepatic vascular anatomy: dynamic contrast-enhanced parallel MR imaging compared with 64 detector row CT.

UNLABELLED The study was approved by the institutional review board, and informed consent was obtained from all patients. The purpose of this study was to retrospectively evaluate the feasibility, reliability, and accuracy of breath-hold dynamic contrast material-enhanced parallel gradient-echo (GRE) magnetic resonance (MR) imaging for mapping the hepatic vascular anatomy, with contrast-enhance...

متن کامل

Liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled gradient echo and balanced steady-state free precession imaging.

PURPOSE To retrospectively evaluate the conspicuity of liver lesions in a fluoroscopic spoiled gradient echo (GRE) and a balanced steady-state free precession (SSFP) magnetic resonance imaging (MRI) sequence. MATERIALS AND METHODS In all, 103 patients with hepatocellular carcinomas (HCC) (41) or liver metastases (67) were treated using MR-guided radiofrequency ablation in a wide-bore 1.5 T sc...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 158 2  شماره 

صفحات  -

تاریخ انتشار 1992