Biological Tissue Modeling with Agar Gel Phantom for Radiation Dosimetry of 99mTc

نویسندگان

  • Liliana Aranda-Lara
  • Eugenio Torres-García
  • Rigoberto Oros-Pantoja
چکیده

The biological tissue has been mimicked and replaced by other materials, which have shown certain radiological similarity determined by attenuation coefficient (μ), density and atomic number. Specifically, in molecular imaging and radiation therapy have been developed multifunctional radiopharmaceuticals which contain beta/gamma and/or light emitters to chronic degenerative diseases treatment. Therefore, it is necessary to develop phantoms that allow optical and radiometric characterization. Since the agar gel has shown to be a medium which allows to model biological tissue in phototherapy studies, the aim of this study is to determine whether the agar gel may be used as biological tissue substitutes in 99mTc dosimetry. Agar gel was prepared to 1% and 2.3% (water:agar) and its radiologicalproperties as: linear attenuation coefficient obtained by narrow beam geometry and XCOM software, density and effective atomic number (Zeff) were determined. Using the determined μ, photontransmission was calculated by Monte Carlosimulation. The 99mTc source region was immersed in a water phantom, two source regions were used, one source region was filled with water and another with agar gel. For both cases; the cumulated activity (  A ) by conjugate view method, the absorbed doseper unitcumulated activity (S) and absorbed dose (D) were determined. The 2.3% concentration gel consistency facilitated its handling during a bigger irradiation time. A 0.151 0.02 1 cm μ = ± was obtained and also this value was corroborated with the XCOM software. The agar gel density was 3 0.999 0.0004 g cm ρ = ± and . eff Z 7 50 = . The calculated cumulated activity presented 1% difference in both phantoms. The absorbed doseper unitcumulated activity was the same in both media, therefore the D too. Agar gel showed to be equivalent to water in terms of radiological properties for 140 keV photons, thus it can substitute soft tissue in 99mTc dosimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

متن کامل

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

متن کامل

Design and manufacturing a CTDI pediatric phantom for CT dosimetry using TLD, ion chambers, and gel dosimetry

Introduction: Nowadays, the demand for CT-scan is increased, and this issue has become a critical subject in radiation protection, because of the risk of cancer especially for children. The quality assurance of CT images is a necessary factor that can effect on children dose. The CT dose index is an important dosimetry index in CT-Scan dosimetry. The purpose of this study is t...

متن کامل

A Dosimetric Evaluation of Organs at Risk in Prostate Radiation Therapy using a MAGIC Gel Dosimeter

Introduction: Multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. In this work, we investigated MR-based MAGIC gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. Materials and Methods: A heterogeneous slab phantom including bones was made....

متن کامل

Verifying the accuracy of dose distribution in Gamma Knife unit in presence of inhomogeneities using PAGAT polymer gel dosimeter and MC simulation

Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study the obtained isodose maps with PAGAT polymer gel dosimeter were compared to those calculated with EGSnrs for singleshot irradiations of 8 and 18 mm collimators of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014