A study on the section sensitivity profile in multi-row-detector spiral CT.

نویسندگان

  • G Wang
  • M Madsen
  • K Redford
  • S Zhao
  • M W Vannier
چکیده

The section sensitivity profile (SSP) was well understood in the case of single-row-detector spiral CT. With the introduction of multi-row-detector spiral CT and the transition into cone-beam spiral CT, a revisit to the SSP issue becomes necessary. In this paper, the SSP of multi-row-detector spiral CT is formulated for the half-scan interpolation method at any transverse position. Based on the SSP formula, numerical simulation is performed to quantify the characteristics of the SSP with the number of detector rows up to 40. It is shown that the SSP varies as a function of the pitch and the number of detector rows. Given an appropriate selection of the pitch and the number of detector rows, the SSP does not change very much over the field of view in terms of the mean, the slice thickness, and the skewness of the SSP. Although in general applications the SSP at the gantry iso-center can be used as the representative of the SSP family, for more accurate analyses the spatial variation of the SSP must be taken into account.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-detector row CT systems and image-reconstruction techniques.

The introduction in 1998 of multi-detector row computed tomography (CT) by the major CT vendors was a milestone with regard to increased scan speed, improved z-axis spatial resolution, and better utilization of the available x-ray power. In this review, the general technical principles of multi-detector row CT are reviewed as they apply to the established four- and eight-section systems, the mo...

متن کامل

Relationship between noise, dose, and pitch in cardiac multi-detector row CT.

In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends ...

متن کامل

Detection of low-contrast objects: experimental comparison of single- and multi-detector row CT with a phantom.

PURPOSE To compare single-detector row computed tomography (CT) and multi-detector row CT by using an experimental phantom containing a contrast-detail modulus for detection of low-contrast structures to optimize acquisition protocols. MATERIALS AND METHODS The parameters milliampere seconds, reconstructed section thickness, and elementary collimation for multi-detector CT were varied for two...

متن کامل

Multiplanar and 3D imaging of the central airways: comparison of image quality and radiation dose of single-detector row CT and multi-detector row CT at differing tube currents in dogs.

PURPOSE To compare in an animal model the image quality of multiplanar reformation and three-dimensional (3D) reconstruction images of the central airways by using single-detector row computed tomography (CT) and multi-detector row CT at varied tube currents and to compare radiation dose. MATERIALS AND METHODS Five dogs each underwent five consecutive helical CT examinations (one single-detec...

متن کامل

Evaluation of Absorbed Dose of Critical Organ in Rando Phantom under Head, Abdomen and Pelvis Spiral CT Scan by Thermo Luminescent Dosimetery - TLD

Background & Objectives: Computed tomography (CT) represents 11% of all diagnostic radiology procedures but it contributes to almost 67% of the total effective dose to the human population. In head and neck CT which consist of 1/3 of total CT scans, other critical organs such as lenses and thyroid are in the radiation field. Also in the abdomen and pelvis scan, irradiation of ovaries is unavoid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of X-ray science and technology

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2003